Control Guide - Advanced (cont)

Control Guide - Advanced (cont)

Button

Action

Display

 

 

 

 

Press to stop the BAKE

The ON light is off when the BAKE TIMER is inactive.

 

TIMER or silence the

 

 

beeper after the BAKE

 

 

TIMER has timed out.

 

 

 

 

PROGRAM

Press to select bake

The PROGRAM window displays the number of the

 

program.

current program.

 

 

 

STEP

Press to select one of

The corresponding indicator light will be lit (1 to 4),

 

four baking steps.

depending on which step is selected.

 

 

 

 

Press to open or

The indicator light above the VENT button is lit when the

 

close the vent.

vent cycle is enabled.

 

 

 

Auto On/Off Timer

Timer Settings

The Auto ON/OFF Timer display shows the current time of day. To adjust time, press the arrow buttons.

The oven can be set to turn itself on and off. After the Auto ON/OFF Timer is set, the POWER ON OFF button can be pressed to turn the oven off. This will not disrupt the AUTO ON/OFF setting. Electrical power to the oven must remain on.

1.To set the oven to turn on, press and hold the AUTO ON TIME button. The previously entered start time will appear in the display. Use the UP and DOWN arrows to adjust the start time. Then release the AUTO ON TIME button.

2.To set the oven to turn off, press and hold the AUTO OFF TIME button. The previously entered end time will appear in the display. Use the UP and DOWN arrows to adjust the end time. Then release the AUTO ON TIME button.

3.To enable the automatic start, press and hold the TIMER ON/OFF button until the indicator LED to the right of the TIMER ON/OFF button is illuminated.

Backup Battery

The clock is backed up by a lithium battery which keeps the clock circuitry operating when all external power is off. If the battery becomes low or dead while the external power is off, the display will read 12:00 (12 hr mode) or 0:00 (24 hr mode) and will not increment until a new time is set. The clock will operate with a dead or missing battery, but must be set each time external power is turned on. Batteries should be replaced when low or dead to avoid corrosive damage to the circuitry. Contact your local Hobart Bakery Systems service office.