Multi-Step Programming

Multi-Step Programming

Additional programs or steps can be entered within the original program number. Up to four individual steps can be added by the operator, each with different bake settings.

For example, Program 1 has temperature, bake, steam and delay time settings set by the operator. This is known as Step 1. After the timer times out in Step 1, the oven automatically starts the programmed bake settings in Step 2. The system continues with each step until all steps have been timed out.

1.With the oven in the OFF mode, press and hold the UP arrow in the STEPS section. While pressing and holding the UP arrow, press the POWER ON OFF button for 3 seconds. When the beep sounds, the oven is in program mode.

2.Press the PROGRAM UP or DOWN arrows until the program number that is desired is displayed. The Step 1 light is lit.

3.Press the TEMP UP or DOWN arrows to enter the desired temperature.

4.Set the Bake, Steam, Delay Airflow and Vent settings:

Press the UP or DOWN arrows next to BAKE TIMER to enter the desired time.

Press the UP or DOWN arrows next to STEAM TIMER to enter the desired time.

Press the UP arrow next to AIRFLOW DELAY to enter the desired time.

NOTE: The steam and airflow delay settings are optional and can be left at 0 if desired.

Press the VENT button to vent the cavity for the entire time of the step. When step is complete, vent will close.

5.Press the UP arrow in the STEPS section to advance to the next step within the program. The selected step light is lit. Repeat steps 3 and 4 above to set each step, if needed, in the program.

6.To store all the steps in the program, press the PROGRAM UP or DOWN arrows to move to the next program number, or press the POWER ON OFF button to exit the program mode.