Relief Valve and Flow Sensor Manifold
Relief Valve and Flow Sensor Manifold
For 120 V sprayer use Relief Valve Replacement Kit 287325.
For 230 V sprayer use Relief Valve Replacement Kit 287350.
Disassembly
First read and follow instructions in the Before performing any service on sprayer section, page 9.
Then remove hopper, front and back covers, page 9.
1Remove air line to regulator.
2 Remove air line from
cooler to manifold.
ti4423a
3Disconnect wires to Relief Valve. Pay attention to their location to insure they are reattached correctly.
4Remove 2 nuts securing Relief Valve to sprayer.
Reassembly
1Position new relief valve from Kit in back of sprayer.
2Replace and tighten screws.
3Reattach wires to Relief Valve.
4Reattach air line from cooler to manifold.
5Reattach air line to regulator.Replace RotoFlex HD Pump and hose extension, page 12.
6Replace front cover and hopper. See Removing and Replacing Hopper, Front and Back Cover, page 9.
ti4418a
5Remove Relief Valve from sprayer frame.
ti4419a
310645K | 25 |