13.Remove all o-rings from the piston (3) and stems (T). Check that the stems are solidly in place. If they are loose, replace the entire piston assembly (3).

14.Perform the following applicable step:

a.Non-circulating guns: Remove the fluid outlet port plug (19), and gasket (22) from the fluid housing (2). Remove the

o-ring (21) and backup (20) from the

plug. See FIG. 20.

b. Circulating guns: Remove the gasket (22) from the fluid housing (2). See FIG. 20.

15.Clean all parts and replace any worn parts. When assembling, lubricate the threads with anti-seize lubricant.

 

 

 

 

 

 

 

T

8* 3

4 2 4

 

 

 

 

 

1 2

10* 3

11* 3

 

 

 

 

 

 

 

 

 

 

 

6

 

 

25

2

2

16 8

 

 

 

 

24

23 1

2

 

 

 

 

 

 

7

30 6 7 29

9 3

3 3

5a

9

5

36

 

 

 

ti8199a

Alternate Fluid Control Shown

FIG. 19

17 3

12*

ti13592a

 

Cutaway View:

Part No. 24A749 Gun Shown

SERVICE NOTES:

1Torque to 35-45 in-lb (4.0-5.1 N•m).

2Lubricate threads with anti-seize lubricant.

3Lubricate with light-weight oil.

4Tighten cap (4) until it bottoms out.

6Apply semi-permanent anaerobic sealant.

7Torque to 4-5 in-lb (0.45-0.57 N•m).

8Torque to 95-105 in-lb (10.7-11.8 N•m).

9Apply semi-permanent anaerobic sealant to two threads at end of needle shaft.