Technical Data
Technical Data
Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) Maximum Working Air Pressure. . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) Maximum HVLP and Compliant Gun
Inbound Air Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . See chart on page 7. Maximum Working Fluid Temperature . . . . . . . . . . . . . . . . 120° F (49° C)
Minimum Air Cylinder Actuation Pressure . . . . . . . . . . . . . 50 psi (0.34 MPa, 3.4 bar) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 lbs (680 g)
Wetted Parts
Models
PEEK
Models
Weight Polyethylene, Acetal, PTFE,
Tungsten Carbide
Triggering Speed
These values apply to a new gun with a 12 ft. (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a 0.055 in. nozzle. These values will vary slightly with use and with variations in equipment.
Cylinder Air | Fluid Pressure | Air Pressure | msec to fully | msec to fully |
Pressure | ||||
psi (kPa, bar) | psi (kPa, bar) | psi (kPa, bar) | open | close |
|
|
|
|
|
50 (0.35, 3.5) | 50 (0.35, 3.5) | 100 (0.7, 7.0) | 58.4 | 50.4 |
|
|
|
|
|
Sound Data
Conventional
Measured at 44 psi (0.30 MPa, 3.0 bar) atomizing air and 47 psi (0.32 MPa, 3.2 bar) fan air pressure
Sound Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88.82 dBa
Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78.91 dBa
HVLP
Measured at 17 psi (0.12 MPa, 1.2 bar) atomizing air and 29 psi (0.20 MPa, 2.0 bar) fan air pressure
Sound Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89.70 dBa Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79.79 dBa
Compliant
Measured at 29 psi (0.20 MPa, 2.0 bar) atomizing air and 33 psi (0.23 MPa, 2.3 bar) fan air pressure
Sound Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87.47 dBa
Sound Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77.56 dBa
Sound power measured per ISO
313516C | 43 |