Repair
18 313889B
Pressure Control

Pump On/Off Switch

Removal
1. Remove two screws (71) and swing down cover
(70a).
2. Disconnect pump ON/OFF switch (70j) connector
from control board.
3. Press in on two retaining tabs on each side of pump
ON/OFF switch (70j) and remove switch from cover.
Installation
1. Install new ON/OFF switch (70j) so tabs of switch
snap into place on inside of cover. Align new
ON/OFF switch with electrical tabs at bottom.
2. Connect pump ON/OFF switch connector to control
board.
3. Swing cover (70a) up and secure with two screws
(71).
ti13709a
71
71
70a
ti13245a
70j
ti13248a
70j
ti13248a
70j
ti13245a
70j
ti13709a
71
71
70a