Repair
20 313889B
Pressure Control TransducerRemoval
1. Remove two screws (71) and swing cover (70a)
down.
2. Disconnect transducer lead (158) from control board
(70c).
3. Remove strain relief (70b) and pull transducer cable
from the control box. Remove screws (182) and
cover (184) to detach transducer from cart frame.
4. Remove pressure control transducer (158) and
o-ring (158b) from manifold.
Installation
1. Install o-ring (158b) and pressure control transducer
(158) in manifold (72). Tighten securely.
2. Place end of transducer in slot of mount (183) and
secure with cover (184) and screws (182). Route
transducer cable through control box and secure
with strain relief (70b).
3. Connect transducer lead (158) to control board
(70c).
4. Swing cover (70a) up and secure with two screws
(71).
ti13709a
71
71
70a
ti13253a
158
70c
ti13801a
70b
ti13800a
158
158b
ti13800a
158
158b
ti13801a
70b
ti13253a
158
70c
ti13717a
71
70a