GROUNDING INSTRUCTIONS

This product mustbe grounded. Ifit should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This equipmentis equippedwith a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and &dunbed in accordance wiih all local codes and ordinances.

DANGER1 -

Improper connection of the equipment- grounding conductor can resultin the risk of electrocution. Check with a qualified electrician or service

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

To comply with the National Electrical Code(NFPA 70) and to provide additional protection from the risk of electricshock, connect this pressure washertoa circuit that is protected by a ground-fault circuit-interrupter (GFCI).

EQUIPMENT MISUSEHAZARD

General Safety

Any misuse of the pressure washeror accessories, such as overpressurizing, modifying parts, using incompatible chemicals and fluids,or using worn or damaged parts, can cause themtorupture andresult in fluid injection, splashing in the eyesor on the skin, or other serious bodily injury, fire, explosion or property damage.

NNER alter or modifyany part of this equipment; doing so could cause itto malfunction.

CHECK all spray equipment regularly and repair or replace worn or damaged parts immediately.

ALWAYS wear protective eyewear and appropriate clothing. If using a chemical injector, read andfollow the chemical manufacturer's literature for recommendations on additionalprotective equipment, such as a respirator.

System Pressure

This sprayer can develop high operating pressure. Be sure thatall spray equipment and accessories arerated to.withstand the maximum working pressure of this sprayer. DO NOT exceed the maximum working pressure of any component or accessory usedin the system.

Chemical Compatibility

BE SURE that all chemicals used in the chemical injector are compatible with the wetted parts of the hose, gun, wand and tip, as giveninthe Technical Data (inside back cover). Always read the chemical manufacturer's literature before using any chemicalin this pressure washer.