Part Number 474754

Grease Grabber™ Power Play

®

Kitchen Exhaust Pollution Control System

Installation, Operation and Maintenance Manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Grease Grabber™ Power Play

The Greenheck Grease Grabber™ Power Play is a pre-engineered electrostatic precipitator type filtration pollution control unit with integral exhaust fan (available without exhaust fan as an option). The unit is designed to remove grease and smoke particles as well as odor molecules from the kitchen exhaust airstream. This installation manual covers procedures for receiving, installing, and maintaining the filtered section of the unit.

For additional instructions and maintenance information on the integral exhaust fan, when applicable, refer to the fan nameplate

to determine model type and visit www.greenheck.com to download the corresponding manual.

General Safety Information

Only qualified personnel should install this system. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be required if high winds or seismic activity are present. If more information

is needed, contact a licensed professional engineer before moving forward.

DANGER

Always disconnect power before working on or near this equipment. Lock and tag the disconnect switch or breaker to prevent accidental power up.

CAUTION

When servicing the fan, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing.

CAUTION

Do not install this equipment in explosive atmospheres.

Follow all local electrical and safety codes, as well as the National Electrical Code (NEC), the National Fire Protection Agency (NFPA), where applicable.

Follow the Canadian Electric Code (CEC) in Canada.

The rotation of the fan wheel is critical. It must be free to rotate without striking or rubbing any stationary objects.

Fan motor must be securely and adequately grounded.

Do not spin fan wheel faster than maximum cataloged fan rpm. Adjustments to fan speed significantly effects motor load. If the fan RPM is changed, the motor current should be checked to make sure it is not exceeding the motor nameplate amps.

Do not allow the power cable to kink or come in contact with oil, grease, hot surfaces or chemicals. Replace cord immediately if damaged.

Verify that the power source is compatible with the equipment.

Never open access doors to a duct while the fan is running.

The precipitator contains safety electrical interlock switches at all maintenance access doors. Do not attempt to defeat these interlocks.

1Grease Grabber™ Power Play Kitchen Exhaust Pollution Control System

Page 1
Image 1
Greenheck Fan 474754 installation manual Installation, Operation and Maintenance Manual, General Safety Information

474754 specifications

The Greenheck Fan 474754 is an advanced ventilation solution designed for commercial and industrial applications. Known for its powerful performance and energy efficiency, this fan caters to a wide range of air movement needs, making it a preferred choice among engineers and facility managers.

One of the standout features of the Greenheck Fan 474754 is its robust construction. Made with high-quality materials, the fan is designed to withstand demanding environments while minimizing wear and tear. The housing is typically constructed from galvanized steel, resulting in outstanding durability and resistance to corrosion.

Equipped with a direct-drive motor, the fan promises lower maintenance costs and higher energy efficiency compared to traditional belt-driven models. The direct drive system eliminates the need for belts and pulleys, reducing the risk of failure and downtime. Moreover, it allows for a more compact design, making installation simpler and space-saving.

The technology behind the Greenheck Fan 474754 also emphasizes noise reduction. With fully integrated sound attenuation features, this fan operates quietly, making it suitable for environments where noise levels need to be kept to a minimum. This is particularly valuable in commercial spaces like offices, restaurants, and healthcare facilities.

Performance-wise, the Greenheck Fan 474754 is designed to deliver high static pressure capabilities, making it effective for applications that require the movement of air against significant resistance. This characteristic is critical for systems involving long duct runs or high-efficiency filters. The fan's adjustable speed motor further enhances versatility, allowing users to tailor airflow rates to their specific needs.

Furthermore, this model is equipped with advanced control options, allowing for automation and remote monitoring. Compatibility with building management systems means the fan can be integrated into an overall HVAC solution, providing users with enhanced control over their indoor environment.

In summary, the Greenheck Fan 474754 is a high-performance, energy-efficient solution ideal for various ventilation applications. Its durable construction, direct-drive motor, noise reduction capabilities, and advanced control options make it a reliable choice for those looking to optimize their air movement solutions in a range of settings. This makes it an invaluable asset for efficient and effective ventilation management.