R

4100-I ACT WOOD INSERT

SECURING LINER TO CHIMNEY RING

There are two options to secure the liner to the chim- ney ring: See Figure 13A.

Option One: If there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner with the supplied hex head bolts 1/4- 20-3/4.

Option Two: Remove the manifold tubes, fiberboard baffle and ceramic blanket. From inside the firebox, pull liner down through the chimney ring below the outer skin. There are two pre-drilled holes in the chim- ney ring 180° apart. Secure the liner with the supplied hex head bolts 1/4-20-3/4.

NOTE: Tabs are shipped from factory in a flat position. Bend upwards 90 degrees.

2 pre-drilled holes on chimney ring under outer skin (access through firebox)

Figure 13A

OUTSIDE AIR INSTALLATION

IMPORTANT!

THE ZERO CLEARANCE

FIREPLACE OUTSIDE AIR MUST BE TURNED TO “ON”

1. Remove plate

2. Re-install plate

Figure 13B

Tools Needed: Phillips Head Screwdriver

1.Remove three screws and cover plate from back side of insert. Save the screws.

2.Re-attach the cover plate using the same screws to front side of the insert as shown in Figure 13B.

3.Repeat same procedure for other side of insert.

NOTE: This insert requires replacement of combustion air. If your home is fairly air-tight, it is recommended that you install outside air. If you are installing into a Mobile Home, outside air is required. See page 9.

September 1, 2008

250-7201E

Page 13

Page 13
Image 13
Hearth and Home Technologies 4100I-GD-B warranty Securing Liner to Chimney Ring, Outside AIR Installation, Re-install plate