R

4100-I ACT WOOD INSERT

INSTALLATION IN CANADA

MASONRY and HEAT-CIRCULATING

(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)

Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chim- ney liner of six inch (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built

Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

Do not remove bricks or mortar from fireplace to accommodate insert.

The face of the fireplace must be sealed to prevent room air passage into the chimney cavity.

The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conven- tional fireplace.

Circulating air chambers may not be blocked.

Leveling Bolts and sheet metal shims

This product shipped with two leveling bolts, and two sheet metal guides for ease in sliding the insert into place when using the leveling bolts. Not all installations will require the use of the leveling bolts. The sheet metal guides are used only when the leveling bolts are necessary. Discard if not

needed.

cut-out view

Leveling Bolt

 

ADJUSTING THE LEVELING BOLTS

It is best to use a 1/2 inch (12.7mm) socket wrench with an extended handle for ease in adjusting bolts to the desired level. The bolts will adjust from 0 to 2 inches (0 - 51mm). You can also reach in and adjust the bolts by hand, although space is limited. Figure 12A.

Reach between side of insert and outer skin

Figure 12A

SHEET METAL GUIDES

Slide each guide under the insert on each side placing them directly under leveling bolts. If they are not directly under the bolts, the bolts may hang up on uneven material when sliding the insert into place. See Figure 12B.

Sheet Metal Shims

Place under leveling bolts and slide insert into place

Leveling Bolts

Figure 12B

Page 12

250-7201E

September 1, 2008

Page 12
Image 12
Hearth and Home Technologies 4100I-NL-B Installation in Canada, Leveling Bolts and sheet metal shims, Sheet Metal Guides