Factory/Field Test Menu
This menu is intended to check product functionality both at the end of the factory line and in the field. This mode is entered by pressing and holding the DOWN key on the display board and Full/Half key on the keypad for
10 seconds. Once the menu is entered, the unit will start with an LED test that lights all LEDs and segments on the display. Navigation is done just like the User Menu. Refer to the table below for operation. Field Test Mode exits after stepping through all modes only – there is not a timeout.
Step | Function | Operation | Description |
|
|
|
|
1 | LED Test | All LEDs ON | Verify that all LEDs turn on. |
|
|
|
|
2 | Firmware Version | Display firmware version | Shows the software version of the control. |
|
|
|
|
3 | Date Code | Display date code/serial ID | Not used with Grind’n Brew® |
|
|
|
|
4 | Non Resetable Bean | Scroll | Shows the total number of seconds the |
| Counter |
| grinder has been grinding |
|
|
|
|
5 | Configuration Inputs | Each digit of the display corresponds to a | Highest Digit (left most): |
|
| configuration input. The input is either | “1” - Double Hopper; |
|
| “0” - disabled or “1” - enabled. | “0” - Single Hopper |
|
|
| Middle Digit (center): |
|
|
| “1” - Always show bean count; |
|
|
| “0” - Don’t show bean count |
|
|
| Lowest Digit (right most): |
|
|
| “1” - Grind’n Brew® Model; |
|
|
| “0” - Grind Only Model |
|
|
|
|
6 | Display Water | Show averaged A/D reading of temperature | Show the current temperature in °F of the |
| Temperature |
| thermistor |
|
|
|
|
7 | Display Water Level 1 | Show averaged A/D reading of water level 1 | If > 500 water level full, |
|
|
| If < 500 water level not full |
|
|
|
|
8 | Display Water Level 2 | Show averaged A/D reading of water level 2 | Not used with Grind’n Brew® |
|
|
|
|
9 | Show Input | Display scrolls “InPut” | Input Test Mode |
|
|
|
|
10 | Input Test | Press each key and the display will show a | Hopper Button: 12 |
|
| number related to that key | Size Button: 10 |
|
|
| Grind/Brew Button: 8 |
|
|
| Down Button: 0 |
|
|
| Up Button: 2 |
|
|
| Start Switch: 16 |
|
|
| Basket Out Switch: 17 |
|
|
| Select Button: advances Factory Test to |
|
|
| Step 11 |
|
|
|
|
11 | Show Output | Display scrolls “outPut” | Output Test Mode |
|
|
|
|
12 | Output Test | Turns on each relay separately. Displays | Scroll through relay outputs with the UP |
|
| “O##“ where: | and DOWN keys. Outputs are as follows: |
|
| ## = 2 digit output number |
|
|
|
| O01: Fill Valve |
|
| IMPORTANT: Each output will be turned | O02: Brew Valve |
|
| ON when its number is on the display | O03: Grind Shutter |
|
| REGARDLESS of temperature or fill | O04: Left Auger Motor |
|
| level. Be CAREFUL not to overfill the | O05: Right Auger Motor |
|
| tank and keep electric items out of the | O06: not used |
|
| way of the brew channel. | O07: Heater |
|
|
| O08: Grinder Motor |
|
|
| O09: Basket Out Light |
|
|
| O10: Ready Light |
|
|
|
|
Grind’n Brew® Coffee Systems | Page 11 |