Installation
Grindmaster Corporation
Shuttle Brewer & Airpot/Shuttle Brewers
For Models P300E, P400E, P400ESHP, RAP300E
Electric Hook-up
Installation cont
Start-up
Shuttle Brewers & Airpot/Shuttle Brewers
Shuttle Brewers & Airpot/Shuttle Brewers
Warning Labels
Hot liquid in brew basket could cause burns Remove with care
Page
Shuttle Brewers & Airpot/Shuttle Brewers
Operation
Brew Volume, Brew Timer
Adjustments
Before making the timer adjustment, do the following
Adjusting the Timer
Two Batch Timer with Knob Adjustment, See Figure
Two Batch Timer with Counter Adjustment, See Figure
Shuttle Brewers & Airpot/Shuttle Brewers
Note The bypass is accurate to + 4% Thermostat Adjustment
To Adjust the Bypass
Standard Mechanical Thermostat
Shuttle Brewers & Airpot/Shuttle Brewers
Shuttle Brewers & Airpot/Shuttle Brewers
See Figure 1 Shut off power and open top cover
After Each Brew
Cleaning
Every Day
Shuttle Brewers & Airpot/Shuttle Brewers
Urn cleaners that have been used successfully
Service
Weekly or Bi-Weekly, Depending on Use
Shuttle Brewers & Airpot/Shuttle Brewers
Drain Water Tank
Service cont
Remove Brew Valve
Remove Heater
Troubleshooting Filling, Heating, and Brewing
Shuttle Brewers & Airpot/Shuttle Brewers
Liquid Level Control, located behind the brewer front panel
Troubleshooting Filling, Heating, and Brewing
Shuttle Brewers & Airpot/Shuttle Brewers
The heating system consists of the following components
Shuttle Brewers & Airpot/Shuttle Brewers
Troubleshooting Filling, Heating, and Brewing
there is always some
small variation from
Description
Parts Illustration for Models P300E & P400E
Description
Shuttle Brewers & Airpot/Shuttle Brewers
Description
Parts Illustration for Model P400ESHP
Description
Shuttle Brewers & Airpot/Shuttle Brewers
Description
Parts Illustration for Model RAP400E
Description
Shuttle Brewers & Airpot/Shuttle Brewers
FRONT
Parts Illustration for Model RAPS400E
Description
Description
Description
Parts Illustration for Model VSB-400
Description
Shuttle Brewers & Airpot/Shuttle Brewers
Parts Illustration for Shuttle CS-LL
Gauge Assembly A718-018
Upper Faucet A537-049
Description
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model P-300
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model P-400 & P-400ESHP
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model RAP-300
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model RAP-400
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model RAPS-300
Rough-In Drawing for Model RAPS-400
Shuttle Brewers & Airpot/Shuttle Brewers
Page
Rough-In Drawing for Model VSB-300
Shuttle Brewers & Airpot/Shuttle Brewers
Page
Shuttle Brewers & Airpot/Shuttle Brewers
Rough-In Drawing for Model VSB-400
STANDARD MODEL ONLY. SEE 091-548 FOR WIRING OF BREWER OPTIONS
Wiring Diagram for P300E/P400E, with 1 Batch Timer
Shuttle Brewers & Airpot/Shuttle Brewers
NOTE THIS DRAWING SHOWS COMPONENTS ON
Shuttle Brewers & Airpot/Shuttle Brewers
Wiring Diagram for P300E/P400E, with 2 Batch Timer
Shuttle Brewers & Airpot/Shuttle Brewers
Wiring Diagram for RAP300E/400E
Shuttle Brewers & Airpot/Shuttle Brewers
Wiring Diagram for RAPS 300/400E
Shuttle Brewers & Airpot/Shuttle Brewers
Wiring Diagram for P-400ESHP
Shuttle Brewers & Airpot/Shuttle Brewers
Wiring Diagram #091-548
NOTE USE WIRE NUT FOR 1 - 1 CONNECTION T3 T3 T3 1 1 T4 A
Wiring Diagram #091-182
Shuttle Brewers & Airpot/Shuttle Brewers
T2 T3 T3 T4 T4 T4 B A T2 T3 T3 1 1 T1 C T3 T3 T3 T1 T1 T4 D
Grindmaster Corporation
P.O. Box 35020 Louisville, KY 40232 USA
0307 Form # AM-309-08
090-077