Grindmaster P400ESHP Wiring Diagram #091-182, Shuttle Brewers & Airpot/Shuttle Brewers

Models: P400ESHP

1 36
Download 36 pages 41.73 Kb
Page 35
Image 35
Wiring Diagram #091-182

Wiring Diagram #091-182

NOTE: USE WIRE NUT FOR 1 - 1 CONNECTION

T3 T3 T3 1 1 T4 A

T2 T3 T3 T4 T4 T4 B

A T2 T3 T3 1 1 T1 C

T3 T3 T3 T1 T1 T4 D

T2 T3 T3 T1 T1 T4 E

T2 T3 T3 T1 T1 T2 F

5000 WATT / 240V HEATERS

 

FOR THIS HEAT AND ELECTRIC SERVICE

WIRE PER FIG.

 

 

 

2.0

KW - 120/208V - 1 PH - 3 WIRE - 9 AMPS

A

2.5

KW - 120/240V - 1 PH - 3 WIRE - 11 AMPS

 

4.0

KW - 120/208V - 1 PH - 3 WIRE - 18 AMPS

B

5.0

KW - 120/240V - 1 PH - 3 WIRE - 21 AMPS

 

5.5

KW - 120/208V - 1 PH - 3 WIRE - 27 AMPS

C

7.5

KW - 120/240V - 1 PH - 3 WIRE - 31 AMPS

 

7.5

KW - 120/208V - 1 PH - 3 WIRE - 38 AMPS

D

10.0 KW - 120/240V - 1 PH - 3 WIRE - 42 AMPS

 

11.5 KW - 120/208V - 1 PH - 3 WIRE - 54 AMPS

E

15.0 KW - 120/240V - 1 PH - 3 WIRE - 63 AMPS

 

11.5 KW - 120/208V - 3 PH - 4 WIRE - 31 AMPS

F

15.0 KW - 240V - 3 PH - 3 WIRE - 36 AMPS *

 

* SEPARATE 120V REQUIRED FOR CONTROLS (3 AMP LOAD)

*FOR 3 PHASE WIRING

1.MOVE WIRE 6 FROM L1 TO L3

2.CONNECT HEATER ACCORDING TO FIG. F ON CHART

3.FIG. F FOR 3 PH ONLY

WIRES 5 6 7 8 ARE 8 AWG, 105°C

1 2 3 4 ARE 10 AWG, 105°C

Shuttle Brewers & Airpot/Shuttle Brewers

Page 35

Page 35
Image 35
Grindmaster P400ESHP instruction manual Wiring Diagram #091-182, Shuttle Brewers & Airpot/Shuttle Brewers