| FILLING PROBLEMS | ||
|
|
|
|
| Problem/Cause | Remedy | |
Overfilling of water tank when power is off |
| • Disassemble, clean and reassemble valve. If needed service | |
| |||
| • Fill valve not sealing properly |
| |
|
|
| kits are available |
Overfilling of water tank when power is on |
|
| |
| • Fill valve not sealing properly |
| • Disassemble, clean and reassemble valve. If needed service |
| • Fill valve not |
| kits are available |
|
| • Check wiring of timer, switches and fill valve, if o.k. | |
|
|
| then defective timer board |
|
|
|
|
| HEATING PROBLEMS | ||
|
|
| |
| Problem/Cause | Remedy | |
Water is hot but hot light not illuminated |
| • Replace light | |
| |||
| • Light burned out |
| |
Water tank will not heat |
| • Recalibrate thermostat. If no remedy or thermostat does | |
| • Thermostat faulty or out of calibration |
| |
|
|
| not cycle, replace thermostat |
| • Bad electrical connection of heating circuit |
| • Check each electrical connection of heating circuit |
Recovery time is very long |
| • Check each electrical connection of heating circuit | |
| • Bad electrical connection of heating circuit |
| |
| • Bad high limit switch |
| • Check resistance across high limit switch, should be no |
|
|
| resistance. If resistance present then replace |
| • Faulty heating element |
| • Check resistance across element with power conductors |
|
|
| disconnected. If resistance is much less than 8 Ohms or |
|
|
| much more than 15 Ohms, replace part |
|
|
|
|
If you still need help, call our service department at (800)
Prior authorization must be obtained from Grindmaster Corporation’s Technical Service Department for all warranty claims.
American Metal Ware® Tea Brewers | Page 10 |