Timer Adjustment (cont.)
3.This timer is adjustable from 15 seconds to 8 minutes.
4.Make the desired adjustments by turning the adjusting knob clockwise to increase timer setting; turning counter clockwise to reduce time.
5.
Thermostat Adjustment
Change thermostat setting if spray over water temperature requires adjustment. Factory setting is 195°F (90.56°C). This is the ideal temperature for brewing tea. Water should never boil in the tank. If water is boiling in the tank, adjust the temperature appropriately.
1.Shut off power and unplug the brewer.
2.Remove the screw fastening the top cover. Remove the top cover by pulling forward and upwards.
3.Locate thermostat mounted on tank.
4.Turn the shaft clockwise to increase the water temperature, counter clockwise to decrease water temperature. (Refer to Figure B.)
5.
Figure B
Bypass Adjustment
Change bypass adjustment if desired volume of brewed liquid requires adjustment.
1.Shut off power and unplug the brewer.
2.Remove the lower front panel by removing the screws securing the panel.
3.Make the desired adjustments by turning the adjusting knob clockwise to decrease the total brewed volume; turning counter clockwise to increase volume.
Cleaning Procedures
Figure C
! WARNING: BURN HAZARD
HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT. TO AVOID BURNS USE CAUTION WHEN CLEANING. RINSE HOT PARTS WITH COLD WATER BEFORE CLEANING. USE GLOVES OR HEAVY CLOTH WHEN REMOVING HOT PARTS FROM BREWER.
Cleaning After Each Brew
Dispose of used tealeaves and rinse brew basket.
American Metal Ware® Tea Brewers | Page 6 |