SECTION 2: CIRCUIT

REQUIREMENTS

220V/440V Connection

Hard wire this machine to a power panel that has proper overload protection and a locking shut-off lever (Figure 6). If you are unsure about electri- cal wiring, consult a qualified electrician before attempting any wiring.

Figure 6. Locking Shut-Off Lever.

Grounding

Electrocution or fire may result if machinery is incor- rectly grounded or the power supply violates local and state codes. Contact a qualified electrician for safe wiring practices!

G0486/G0487 Wide Belt Sander

Amperage Loads

The following list outlines the electrical phase and voltage required to operate the Model G0486/ G0487, as well as the amperage draw of their motors and circuit requirements.

Note: If you do not have three-phase power avail- able, you will have to install a phase converter such as the Grizzly Phase Converter.

Amperage Draw Specifications:

G0486—220V, Three-Phase ~90 Amp Circuit

25 HP Sanding Motor

............................ 64

Amps

2 HP Feed Motor

6

Amps

14 HP Table Motor

1.2

Amps

G0486—440V, Three-Phase ~50 Amp Circuit

25 HP Sanding Motor

............................ 32

Amps

2 HP Feed Motor

3

Amps

14 HP Table Motor

0.6 Amp

G0487—220V, Three-Phase ~100 Amp Circuit

30 HP Sanding Motor

............................ 72

Amps

2 HP Feed Motor

6

Amps

14 HP Table Motor

1.2

Amps

G0487—440V, Three-Phase ~50 Amp Circuit

30 HP Sanding Motor

............................ 36

Amps

2 HP Feed Motor

3

Amps

14 HP Table Motor

0.6 Amp

Extension Cords

Do not use an extension cord with 220V/440V machinery. An extension cord increases the risk of electrocution and fire. Instead, position your equipment near the power supply to eliminate the extension cord requirement.