SECTION 2: CIRCUIT REQUIREMENTS

220 3-Phase

Serious personal injury could occur if you connect your machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G0489 features a 220V motor that draws the following amps under maximum load:

Motor Draw at 220V

11 Amps

Circuit Requirements

We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire hazard—consult a qualified electrician to reduce this risk.

220V Circuit Breaker

15 Amps

-8-

Connection Type

Recommended connection type (see Figures 2 &

3 for an example):

220V

Locking Shut-Off Switch

Figure 2. A locking shut-off switch near the

machine.

��������

����������

�������

��������

������

�������������

Figure 3. 15-15R plug and receptacle.

G0489 Metalworking Sander

Page 10
Image 10
Grizzly G0489 owner manual Circuit Requirements, 220 3-Phase