SECTION 7: SERVICE
Review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel- ops. If you need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support at (570)
Troubleshooting
Motor & Electrical
Symptom |
| Possible Cause | Possible Solution | |||
Machine | does not | 1. | Fuse/breaker has blown. | 1. | Correct short/replace fuse/replace breaker. | |
start or | a | fuse/ | 2. | Switch disabling key is removed or at fault. | 2. | Install/replace switch disabling key; replace switch. |
breaker trips. |
| 3. | Motor is at fault. | 3. | Correct motor wiring connections or replace bad | |
|
|
|
|
|
| motor. |
|
|
| 4. | Capacitor is at fault. | 4. | Replace capacitor. |
|
|
|
|
|
|
|
Machine | has | vibra- | 1. | Fan is bent or loose. | 1. | Adjust fan balance or replace fan. |
tion or noisy opera- | 2. | Motor or component is loose. | 2. | Inspect/replace stripped or damaged bolts/nuts, and | ||
tion. |
|
|
|
|
| |
|
|
|
|
|
|
|
Operations
Symptom | Possible Cause | Possible Solution | ||
|
|
|
|
|
Downdraft table | 1. | Dust collection drawer is full. | 1. | Empty collection drawer. |
does not adequately | 2. | Filter is dirty. | 2. | Knock dust off filter. If this has no effect, replace with |
collect dust; poor |
|
|
| new filter unit. |
performance. |
|
|
| |
|
|
|
| |
|
|
|
|
|
G0631 79" x 28" Downdraft Table |