Grizzly G0631 Circuit Requirements, 110V Operation, Amperage Draw, Circuit Recommendations

Models: G0631

1 32
Download 32 pages 55.14 Kb
Page 10
Image 10
SECTION 2: CIRCUIT REQUIREMENTS

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

Each Model G0631 motor draws the following amps under maximum load:

Motor Draw

12 Amps

Circuit Recommendations

We recommend connecting EACH motor to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

110V Circuit..................... 15 Amps (Each Motor)

Plug/Receptacle Type

Included Plug Type

NEMA 5-15

 

 

 

 

Figure 2. Typical type 5-15 plug and receptacle.

-8-

Electrocution or fire could result if this machine is not grounded correctly or if your electrical configu- ration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician!

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

We do not recommend the use of extension cords, but if you find it absolutely necessary:

Use at least a 14 gauge cord that does not exceed 50 feet in length!

The extension cord must also contain a ground wire and plug pin.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.

G0631 79" x 28" Downdraft Table

Page 10
Image 10
Grizzly G0631 Circuit Requirements, 110V Operation, Amperage Draw, Circuit Recommendations, Plug/Receptacle Type