Grizzly owner manual Model G0637 Control Box, Model G0638 Control Box

Models: G0637

1 60
Download 60 pages 39.09 Kb
Page 28
Image 28
Model G0637 Control Box

9.Secure the collection drum lids to the collec- tion drums with the lid latches.

10.Connect the dust collection drum assemblies to the funnel port with the 9" flexible ducts and 9" duct clamps (see Figure 38).

Figure 38. Dust collection drum assemblies

connected to funnel port.

Model G0637 Control Box

1.Mount the control box onto the lower stand brace with (2) 38"-16 x 34" hex bolts, (4) 38" flat washers, and (2) 38"-16 hex nuts (see Figure 39).

Figure 39. Model G0637 control box mounted.

Note: The remote control uses IR (infrared) to communicate with the control box, and must have direct line-of-sight to the control box. Locate the control box with this in mind.

-26-

Model G0638 Control Box

1.Mount the control bracket onto the lower stand brace with (2) 38"-16 x 34" hex bolts, (4) 38" flat washers, and (2) 38"-16 hex nuts (see Figure 40).

Figure 40. Model G0638 control box bracket

mounted.

2.Open the control box and identify the four mounting holes in the back of the cabinet.

3.Attach the control box to the bracket already mounted on the stand brace with (4) M6-1 x 15 Phillips head screws, (4) 6mm flat wash- ers, and (4) M6-1 hex nuts (see Figure 41).

Figure 41. Model G0638 control box mounted.

G0637/G0638 Cyclone Dust Collector

Page 28
Image 28
Grizzly owner manual Model G0637 Control Box, Model G0638 Control Box