SECTION 2: CIRCUIT REQUIREMENTS
110V Operation | 220V Operation | |
|
|
|
|
|
|
The G8793 Sander motor is prewired to operate at 110V. A 110V plug is included with this machine. The plug must be used in a grounded receptacle similar to that shown in Figure 1.
Under normal 110V use, the motor draws approx- imately 20 amps. We recommend a 20 amp cir- cuit breaker or a 20 amp
Grizzly recommends that the circuit you use should be dedicated, (i.e., the G8793 should pro- vide the only draw from that circuit). If frequent circuit failures occur when using this machine, contact our Service Department or your local electrical contractor.
Figure 1. Typical 110V 3-prong plug and outlet.
The motor supplied with the G8793 can be oper- ated at either 110V or 220V. The motor comes pre wired for 110V. Refer to the wiring diagram inside the motor cover for information about con- verting to operate at 220V.
If converting to operate at 220V, a suitable 220V plug must be wired in. When operating at 220V, we recommend using a NEMA-style 6L-15 plug and outlet. See Figure 2. You may also “hard- wire” the machine directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring requirements.
Under normal use, the motor draws approximate- ly 10 amps @ 220V. We recommend a 15 amp circuit breaker for 220V operation This should be satisfactory for normal use while providing enough protection against motor damage caused by power surges.
Figure 2. Typical 220V 3-prong plug and outlet.
|
|
|
|
|
|
|
|
|
|
|
|
G8793 12" Double Disc Sander |