SECTION 3: CIRCUIT REQUIREMENTS

110 Volt

Amperage Draw

The Model G8976 motor is wired to operate at

110V and will draw the following load:

Motor Load

4.5 Amps

Plug Type

The Model G8976 is supplied with a NEMA 5-15 plug. DO NOT modify the plug or power cord in any way. See Figure 1 for a NEMA 5-15 plug and grounded outlet.

Figure 1. NEMA 5-15 plug and grounded outlet.

Circuit Breaker Requirements

We recommend that the circuit you use your machine on should be dedicated. Because the machine motors are different sizes, please use the following guidelines when choosing a circuit breaker for your machine (circuit breakers rated any higher are not adequate to protect the cir- cuit):

Recommended Circuit Breaker

10 Amp

Your Circuit Capacity

Always check to see if the wires in your circuit are capable of handling the amperage load from your machine. If you are unsure, consult a qualified electrician.

If you operate this machine on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist and a power failure still occurs, contact a qualified electrician or our Service Department at (570) 546-9663.

Serious personal injury could occur if you connect your machine to the power source before you have completed the assembly process. DO NOT connect the machine to the power source until instructed to do so.

-6-