Grizzly G9743 owner manual Circuit Requirements, 110/220V Operation, Wiring for

Models: G9743

1 56
Download 56 pages 54.92 Kb
Page 12
Image 12

SECTION 2: CIRCUIT REQUIREMENTS

110/220V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G9743 features 110/220V motor that is prewired for 110V and draws the following amps under maximum load:

Motor Draw at 110V

23

Amps

Motor Draw at 220V

11.5

Amps

Circuit Requirements

We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire hazard—consult a qualified electrician to reduce this risk.

110V Circuit Breaker

25 Amps

220V Circuit Breaker

15 Amps

-10-

Wiring for 220V

The Model G9743 can be rewired to operate on a 220V power source. The motor must be rewired according to the wiring diagram on the motor label. The wiring configuration can also be found on the inside of the motor wire cover, as well as on Page 39.

Plug Type

The Model G9743 comes prewired with a NEMA 5-15 plug. If you wish to rewire the motor to 220V you will need the following 220V plug (see Figure

2 for an example):

220V Plug & Receptacle

6-15

 

 

 

 

 

 

 

 

 

Figure 2. 6-15 plug and outlet.

G9743 7" x 12" Metal-Cutting Bandsaw