TROUBLESHOOTING

Symptom

Possible Cause

Solution

 

Air leaking at trig-

1. O-rings in trigger valve housing

1.

O-rings must be replaced

ger valve area.

 

are damaged.

 

& operation of safety nose

 

 

 

 

 

 

must be checked.

 

 

 

 

 

 

 

Air leaking.

 

1. Loose screws in housing.

1.

Tighten screws.

 

 

 

 

2.

Damaged O-ring(s).

2.

Replace O-ring(s).

 

 

 

 

3.

Loose air fitting.

3.

Tighten air fitting & use tef-

 

 

 

 

 

 

lon tape.

 

 

 

 

4.

Damaged housing gasket(s).

4.

Replace gasket(s).

 

 

 

 

 

 

 

Tool

skips

nails

1. Excessive air pressure.

1.

Reduce air pressure to tool.

while discharging.

2. Air leaks.

2.

Tighten screws and fittings.

 

 

 

3.

Dirt in nose.

3.

Clean nose.

 

 

 

 

4.

Dirt or damage prevents nails

4.

Clean magazine and

 

 

 

 

 

from moving freely in maga-

 

inspect/repair damage.

 

 

 

 

zine.

 

 

 

 

 

 

 

5.

Inadequate air flow to tool.

5.

Check fitting, hose, com-

 

 

 

 

 

 

pressor & air pressure.

 

 

 

6.

Worn O-ring on piston or lack

6.

Replace piston O-ring.

 

 

 

 

of lubrication.

 

Lubricate.

 

 

 

 

7.

Damaged O-rings on trigger

7.

Replace trigger valve O-

 

 

 

 

valve.

 

rings.

 

 

 

 

 

8.

Worn bumper.

8.

Replace bumper.

 

 

 

 

9.

Cap seal leaking.

9.

Replace cap seal.

 

 

 

 

 

 

 

 

Tool

runs

slowly

1. Undersized air hose.

1.

Use a larger air hose.

 

or has a loss of

2. Nailer is not lubricated.

2.

Lubricate nailer.

 

power.

 

3.

Broken spring in cap assem-

3.

Replace spring.

 

 

 

bly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Exhaust port in cap is blocked.

4.

Clean or replace damaged

 

 

 

 

 

 

internal parts.

 

 

 

 

5.

Air pressure too low.

5.

Increase air pressure.

 

 

 

 

 

 

Fasteners frequent-

1. Nails are the wrong size.

1.

Use correct nails.

 

ly jam the nailer.

2. Nails are bent or dirty.

2.

Use

undamaged,

clean

 

 

 

 

 

 

nails.

 

 

 

 

 

3.

Magazine or nose screws are

3.

Tighten magazine.

 

 

 

 

 

loose.

 

 

 

 

 

 

 

4.

Driver or driver guide are worn

4.

Replace worn or damaged

 

 

 

 

or damaged.

 

parts.

 

 

 

 

 

 

5.

Use correct angle nails.

 

 

 

5.

Nails are wrong angle.

 

 

 

 

 

 

 

 

 

 

 

 

Nailer does not fire.

1. Nailer is not lubricated.

1.

Lubricate nailer.

 

 

 

 

2.

Nail is jammed in magazine or

2.

Clear

nailer magazine or

 

 

 

 

discharge area.

 

discharge area.

 

 

 

 

3.

Piston shaft is damaged.

3.

Replace piston shaft.

 

 

 

 

4.

Air pressure too low.

4.

Check/increase air

pres-

 

 

 

 

 

 

sure.

 

 

 

 

 

 

 

 

 

 

 

Model H8235 3-Piece Framing/Brad/Palm Nailer Kit

-21-

Page 23
Image 23
Grizzly H8235 owner manual Troubleshooting, Symptom Possible Cause Solution