Grizzly specifications T10499 Circuit Requirements, T10500 Circuit Requirements

Models: T10499

1 20
Download 20 pages 5.41 Kb
Page 5
Image 5

T10499 Circuit Requirements

This machine is prewired to operate on a 115V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

115V

Cycle

60 Hz

Phase

Single-Phase

Power Supply Circuit

15 Amps

Plug/Receptacle

NEMA 5-15

This machine is equipped with a power cord and plug that have an equipment-grounding wire and a grounding prong (see Figure 3). The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances.

GROUNDED

5-15 RECEPTACLE

Grounding Prong

5-15 PLUG

Neutral Hot

Figure 3. Typical 5-15 plug and receptacle.

T10500 Circuit Requirements

This machine is prewired to operate on a 230V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

230V

Cycle

60 Hz

Phase

Single-Phase

Power Supply Circuit

20 Amps

Plug/Receptacle

NEMA 6-20

The provided power cord and the plug specified above have an equipment-grounding wire and a grounding prong. The plug must only be inserted into a matching receptacle (outlet) that is prop- erly installed and grounded in accordance with all local codes and ordinances (see Figure 4).

GROUNDED

6-20 RECEPTACLE

Current Carrying Prongs

6-20 PLUG

Grounding Prong

Figure 4. Typical 6-20 plug and receptacle.

SHOCK HAZARD!

Two-prong outlets do not meet the grounding requirements for this machine. Do not modify or use an adapter on the plug provided—if it will not fit the outlet, have a qualified electrician install the proper outlet with a verified ground.

No adapter should be used with the required plug. If the plug does not fit the available receptacle, or the machine must be reconnected for use on a different type of circuit, the reconnection must be made by a qualified electrician and comply with all local codes and ordinances.

T10499/T10500 Blade Welder

-5-

Page 5
Image 5