10. Electrical Load Information
PNEG-338 Portable Dryer Installation Manual 27
1214S
1 PH 230V
Top Auger 526
252 148 350
C303B 100
Bottom Auger 5 26 C303B 100
(2) Fans (2) 10 to 12 96 F614B 100
(2) Auxiliary (2) 7.5 62 C330B *
3 PH 220V
Top Auger 513.2
176 92.4 225
C163B 60
Bottom Auger 5 13.2 C163B 60
(2) Fans (2) 10 to 12 66 C366B 60
(2) Auxiliary (2) 10 52 C303B *
3 PH 440V
Top Auger 56.6
93 46.2 150
C867A 60
Bottom Auger 5 6.6 C867A 60
(2) Fans (2) 10 to 12 33 C180B 60
(2) Auxiliary (2) 10 26 C163B *
1218S
1 PH 230V
Top Auger 526
252 148 350
100
Bottom Auger 5 26 100
(2) Fans (2) 10 to 12 96 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 513.2
165 82.4 225
60
Bottom Auger 5 13.2 60
(2) Fans (2) 10 56 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 56.6
87 41.2 150
60
Bottom Auger 5 6.6 60
(2) Fans (2) 10 28 60
(2) Auxiliary (2) 10 26 *
1220S
1 PH 230V
Top Auger 7.5 31
332 218 400
100
Bottom Auger 7.5 31 100
(2) Fans (2) 10 to 17 156 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 7.5 20
235 118 300
90
Bottom Auger 7.5 20 90
(2) Fans (2) 15 78 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
123 59 200
60
Bottom Auger 7.5 10 60
(2) Fans (2) 15 39 60
(2) Auxiliary (2) 15 39 *
1222S
1 PH 230V
Top Auger 7.5 31
332 218 400
100
Bottom Auger 7.5 31 100
(2) Fans (2) 10 to 17 156 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 7.5 20
235 118 300
90
Bottom Auger 7.5 20 90
(2) Fans (2) 15 78 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
123 59 200
60
Bottom Auger 7.5 10 60
(2) Fans (2) 15 39 60
(2) Auxiliary (2) 15 39 *
*Auxiliaries run through load and unload breakers.
Dryer
Model # Volt age M otor HP Fuel Load
Amps Maximum Amps
with Auxiliaries Minimum
Amps Recommended
Service in Amps Branch Breaker
in Amps