10. Electrical Load Information
PNEG-338 Portable Dryer Installation Manual 25
1126
3 PH 220V
Top Auger 10 26
277 154 400
90
Bottom Auger 10 26 90
Fan 40 102 125
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 10 13
143 77 250
60
Bottom Auger 10 13 60
Fan 40 51 90
(2) Auxiliary (2) 15 39l *
1214
1 PH 230V
Top Auger 526
252 148 300
100
Bottom Auger 5 26 100
Top Fa n 10 to 12 48 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 5 13.2
170 87.4 225
60
Bottom Auger 513.2 60
Top Fa n 10 28 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 56.6
90 43.7 150
60
Bottom Auger 5 6.6 60
Top Fa n 10 14 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 10 26 *
1216
1 PH 230V
Top Auger 5 26
286 178 400
100
Bottom Auger 526 100
Top Fan 10 to 17 78 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 513.2
183 98.4 225
60
Bottom Auger 5 13.2 60
Top Fa n 15 39 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 5 6.6 60
Bottom Auger 56.6
96 49.2 150
60
Top Fan 15 19.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 10 26 *
*Auxiliaries run through load and unload breakers.
Dryer
Model # Volta ge Motor HP Fuel Load
Amps Maximum Amps
with Auxiliaries Minimum
Amps Recommended
Service in Amps Branch Breaker
in Amps