26 PNEG-338 Portable Dryer Installation Manual
10. Electrical Load Information
1218
1 PH 230V
Top Auger 526
286 178 400
100
Bottom Auger 526 100
Top Fa n 10 to 17 78 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 513.2
183 98.4 225
60
Bottom Auger 513.2 60
Top Fa n 15 39 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 56.6
96 49.2 150
60
Bottom Auger 56.6 60
Top Fa n 15 19.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 10 26 *
1220
1 PH 230V
Top Auger 7.5 31
298 188 400
100
Bottom Auger 7.5 31 100
Top Fa n 10 to 17 78 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 7.5 20
229 112 300
90
Bottom Auger 7.5 20 90
Top Fa n 15 39 60
Bottom Fan 10 to12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
123 59 200
60
Bottom Auger 7.5 10 60
Top Fa n 15 19.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
1222
3 PH 220V
Top Auger 7.5 20
241 123 350
90
Bottom Auger 7.5 20 90
Top Fa n 20 50 90
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
129 64.5 200
60
Bottom Auger 7.5 10 60
Top Fa n 20 25 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
1226
3 PH 220V
Top Auger 10 26
271 149 350
90
Bottom Auger 10 26 90
Top Fa n 25 64 90
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 10 13
144 77.5 200
60
Bottom Auger 10 13 60
Top Fa n 25 32 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
*Auxiliaries run through load and unload breakers.
Dryer
Model # Voltage Motor HP Fuel Load
Amps Maximum Amps
with Auxiliaries Minimum
Amps Recommended
Service in Amps Branch Breaker
in Amps