28 PNEG-338 Portable Dryer Installation Manual
10. Electrical Load Information
1226S
3 PH 220V
Top Auger 10 26
307 180 400
90
Bottom Auger 10 26 90
(2) Fans (2) 25 128 90
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 10 13
158 90 200
60
Bottom Auger 10 13 60
(2) Fans (2) 25 64 60
(2) Auxiliary (2) 15 39 *
1314
1318
1 PH 230V
Top Auger 526
307 196 400
100
Bottom Auger 526 100
Top Fa n 10 to 12 48 100
Mid.Fan 10 to 12 48 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 513.2
214 125.4 250
60
Bottom Auger 513.2 60
Top Fa n 10 to 12 33 60
Mid.Fan 10 to 12 33 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 10 52 *
3 PH 440V
Top Auger 56.6
112 62.7 200
60
Bottom Auger 56.6 60
Top Fa n 10 to 12 16.5 60
Mid.Fan 10 to 12 16.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 10 26 *
1322
1 PH 230V
Top Auger 7.5 31
318 206 400
100
Bottom Auger 7.5 31 100
Top Fa n 10 to 12 48 100
Mid.Fan 10 to 12 48 100
Bottom Fan 10 to 12 48 100
(2) Auxiliary (2) 7.5 62 *
3 PH 220V
Top Auger 7.5 20
260 139 350
90
Bottom Auger 7.5 20 90
Top Fa n 10 to 12 33 60
Mid.Fan 10 to 12 33 60
Bottom Fan 10 to 12 33 60
(2) Auxiliary (2) 15 78 *
3 PH 440V
Top Auger 7.5 10
135 69.5 200
60
Bottom Auger 7.5 10 60
Top Fa n 10 to 12 16.5 60
Mid.Fan 10 to 12 16.5 60
Bottom Fan 10 to 12 16.5 60
(2) Auxiliary (2) 15 39 *
*Auxiliaries run through load and unload breakers.
Dryer
Model # Voltage Motor HP Fuel Load
Amps Maximum Amps
with Auxiliaries Minimum
Amps Recommended
Service in Amps Branch Breaker
in Amps