Guardian Technologies ACT1000, ACT2000 Display Log, Print Log, Filter Log ACT 2000 Only

Models: ACT1000 ACT2000

1 35
Download 35 pages 61.96 Kb
Page 10
Image 10

ACT1000/2000 Operating Instructions

Software Version 3.23-00

Display Log

The Display Log function allows the operator to view events in the historical log directly on the LCD display. When this option is selected, the latest event in the log is displayed with the time and date on the top line of the display, and the event details being scrolled across the bottom line. Each log event will be displayed in turn (stepping backwards in time) until the end of the log is reached. Pressing the 0 key advances immediately to the previous event without waiting for it to be displayed. Pressing the key locks the current event on the display until is pressed again. Pressing the key exits from the display log function.

Print Log

The Print Log function allows the user to request the immediate printing of the entire system log on an attached serial printer. If real-time log printing is enabled, new events will be buffered until the complete log print is completed. Note that selection of this function only starts the log printing, and this may take a few minutes to complete. The display will indicate that printing has commenced, and return to the previous menu. If this function is re-selected before the log has been completely printed, then the option to stop the printout is given.

ACT Recommend the Epson LQ-300:

 

Wiring between Printer & Controller: Controller

Printer

0v TX RX

SERIAL (25 way connector)

0V----------------------

PIN 7

TX----------------------

PIN 3

RX----------------------

PIN 20

Printer settings:

CHARACTER TABLE PC850

PAGE LENGTH OF TRACTOR 11 INCHES

SKIP OVER PERFORATION OFF

AUTO TEAR OFF OFF

GRAPHIC PRINT DIRECTION BI-D

SOFTWARE ESC/P2

AGM OFF

AUTO LINE FEED OFF

INTERFACE SERIAL

BIT RATE 9600BPS

PARITY BIT NONE

DATA LENGTH 8 BITS

EXT/ACK OFF

STATE REPLY OFF

Filter Log (ACT 2000 Only)

The Filter Log function allows the user to prevent certain events from being entered on the system log. Normally all events are logged, but to prevent ACTWinPro from having to store a lot of information on a large installation, some events may be filtered out.

The event types that can be filtered are access granted, access denied, alarms (mains fail, tamper etc.), door events (exit button pressed etc.) and others. The 0 key advances to each event type, and the key enables or disables the displayed event type.

The events may also be filtered out on certain doors. Normally all doors are allowed, but the user may prevent certain doors from reporting events.