ACT Single Line RS-485 Converter
12V DC |
|
Power |
|
Supply | 0V |
| |
(300mA) +12V |
Pin | Function |
|
|
1 | +12V |
2 | 0V & Shield |
3 | B |
4 | A |
|
|
4 3 2 1
RS-485 Bus
19200 | BAUDRATE |
9600 | SELECT |
RS-232
ACTWin Software
Network cable is single shielded twisted pair: Belden 9501 or similar
To next Controller
NETWORK |
A B 0V
ACT 2000
A
B 0V
DTR
RX
TX 0V
|
| Battery | NETWORKPRINTER | A | |
|
| 0V | |||
SERIAL/PRINTERDOORS | Timekeeper |
| B | ||
Lithium | TX | ||||
|
|
| |||
|
|
| RX | ||
|
|
|
|
ACT 1000
RS485 line may be up to 1km in length and connect up to 32 controllers
| NETWORK PRINTER | Shield |
Timekeeper Lithium Battery | A | |
B | ||
0V | ||
TX | ||
RX | ||
| ||
ACT 1000 |
|
120R Resistor on last Controller.
Setup for Network Operation
1.From the Controller keypad Enter Installer
2.From ACTWinPro create a new database. In the database creation wizard check
3.Connect to the controllers from ACTWinPro. The LED on the RS485 converter should blink rapidly indicating communications in progress.
Page 29 of 32