Guardian Technologies ACT2000, ACT1000 Interlock Configuration, Fire Override Configuration, Door

Models: ACT1000 ACT2000

1 35
Download 35 pages 61.96 Kb
Page 29
Image 29

Interlock Configuration

 

 

 

 

 

DOOR I/O

 

 

 

 

 

 

SERIAL

NETWORK

 

 

AUX

N/C C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RLY

N/ON/C C N/O

 

5A

OP3

OP2

0V

DOOR CONTACT AUX

PUSH BUTTON

 

 

 

 

 

 

 

GENERAL I/O

RELAY

5A30VDC

250VAC

 

 

 

 

 

 

 

 

5A 250VAC

 

 

 

 

 

LED2

 

5A 30VDC

 

 

 

 

 

 

TAMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

LED1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAINS

 

 

 

 

 

 

 

 

 

 

 

 

SENSE

CLOCK DATA +5V 0V

RED

GREEN

 

+12V

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

P

2

 

Address

ENTRY/EXIT READER

Door 3

 

 

 

 

 

DOOR I/O

 

 

 

 

 

 

SERIAL

NETWORK

 

 

AUX

N/C C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RLY

N/ON/C C N/O

 

5A

OP3

OP2

0V

AUX

DOOR CONTACT

PUSH BUTTON

 

 

 

 

 

 

 

GENERAL I/O

RELAY

5A30VDC

250VAC

 

 

 

 

 

 

 

 

5A 250VAC

 

 

 

 

 

LED2

 

5A 30VDC

 

 

 

 

 

 

TAMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAINS

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSE

CLOCK DATA +5V 0V

RED

GREEN

 

+12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

P

2

 

Address

ENTRY/EXIT READER

 

 

 

 

 

 

 

 

Door 4

 

 

 

 

When Interlock is enabled on a door, the door is locked when the AUX input is active. When the door is open, OP3 is active.

The diagram above shows how to interlock 2 doors. When Door 3 is open, Door 4 is locked and vice versa. Remember to set Interlock for each door to Yes (See Installer Menu > Door Settings > Operation).

To Interlock more doors, simply continue linking OP3 and AUX for each new door, as above.

Fire Override Configuration

While the 0V signal is maintained at the AUX input on Door 1, the doors in the Fire Doors group

FIRE ALARM PANEL

N/C C N/O

FIRE

INPUTS

PUSH

BUTTON

 

 

DOOR

 

CONTACT

1

AUX

INPUT

OUTPUTS

0V

OP2

 

OP3

1A 250VAC 1A 30VDC

BATCH:

98XX-1

PRODUCT: ACT2000 REV2.1

SERIAL NUMBER:

00XXXX

 

 

0 1 2 3 4 5 6 7 8 9

5A 250VAC

5A 30VDC

 

OP3

OUTPUTS

 

OP2

 

0V

 

 

 

AUX

2

 

INPUT

INPUTS

 

DOOR

 

CONTACT

 

PUSH

 

BUTTON

 

1A 1A

 

 

30VDC

 

 

250VAC

5A 250VAC

 

 

5A 30VDC

 

maintain normal operation.

When the 0V signal is removed, the doors are opened, and remain open until, the 0V is restored.

To set the Fire Doors group, go to Installer Menu > System Settings > Fire Doors.

ACT2000

N/C C

N/O N/C C

N/O

TAMPER

MAINS PRESENT

+12VDC

- DC

 

 

 

 

 

 

 

 

 

AUX RLY 1 RELAY 1

N/C C N/O N/C C N/O

AUX RLY 2 RELAY 2

From ACTWinPro, go to View > Options > Doors and select a door group for the Fire Override doors.

Page 26 of 32

Page 29
Image 29
Guardian Technologies ACT2000, ACT1000 installation instructions Interlock Configuration, Fire Override Configuration, Door

ACT1000, ACT2000 specifications

Guardian Technologies, a leader in air purification solutions, offers two standout products in their lineup: the ACT2000 and the ACT1000. Both air purifiers leverage advanced technologies to deliver cleaner, fresher indoor air, making them ideal for families, pet owners, and anyone looking to improve their indoor air quality.

The ACT2000 is designed with a robust filtration system that includes a True HEPA filter capable of capturing 99.97% of airborne particles as small as 0.3 microns. This feature is particularly effective against allergens, dust, mold spores, and pet dander. Additionally, the ACT2000 employs an activated carbon filter that targets and neutralizes odors from cooking, pets, and smoke, ensuring that the air in your home remains fresh and pleasant.

A highlight of the ACT2000 is its innovative UV-C light technology. This feature works synergistically with the filtration system by using ultraviolet light to kill bacteria and viruses present in the air, creating a thorough air purification process. With its coverage of up to 1,250 square feet, the ACT2000 is suited for larger spaces such as living rooms, gyms, or open-concept homes. The device also comes equipped with real-time air quality monitoring, allowing users to track the air quality and adjust settings accordingly.

On the other hand, the ACT1000 is a more compact model, ideal for smaller rooms or offices up to 700 square feet. Similarly, it utilizes a True HEPA filter and an activated carbon filter to purify the air efficiently. While the ACT1000 may be smaller than its counterpart, it does not compromise on performance. The UV-C light technology is included to ensure that airborne pathogens are effectively neutralized.

Both models feature smart controls that allow users to operate the air purifiers remotely. With multiple fan speeds and a whisper-quiet operation, both units can run unobtrusively in the background, even while you’re sleeping or working. An intuitive filter replacement indicator alerts users when it’s time to change the filters, making maintenance simple and straightforward.

In summary, the Guardian Technologies ACT2000 and ACT1000 epitomize modern air purification with their combination of HEPA filtration, activated carbon, UV-C technology, and user-friendly features. Whether you choose the larger capacity of the ACT2000 or the compact efficiency of the ACT1000, both models offer an effective solution for creating a healthier indoor environment.