Guardian Technologies ACT2000 Operation PIN Only, Second Door1, Limiting2 One-To-One, Multiple

Models: ACT1000 ACT2000

1 35
Download 35 pages 61.96 Kb
Page 15
Image 15

ACT1000/2000 Operating InstructionsSoftware Version 3.23-00

Installer Menu

 

System Settings

 

 

Operation

 

 

PIN Only

 

 

PIN’s alone are used to gain access

 

 

 

 

 

 

 

Learn

 

 

Users 1-1/2000 may use random coded cards

 

 

 

 

 

 

 

Ext. Keypad1

 

 

Use external ACT20 keypad

 

 

 

 

 

 

 

KPD Release1

 

 

Key is exit button.

 

 

 

 

 

 

 

Exit PIN’s

 

 

Exit PIN’s may be used in PIN only mode

 

 

 

 

 

 

 

Second Door1

 

 

Second (Auxiliary) door enabled on ACT1000

 

 

 

 

 

 

 

User

 

 

Prevent access if the user limit is reached

 

 

 

 

 

 

 

Limiting2

 

 

 

 

 

 

 

 

 

 

 

One-To-One

 

 

Card numbers may be assigned to Users 1-

 

 

 

 

 

 

 

Multiple

 

 

1000/2000

 

 

 

 

 

 

 

 

 

Users may have multiple cards

 

 

 

 

Display

 

 

 

 

 

Keypad backlight enabled

 

 

 

 

 

 

Backlight

 

 

 

 

 

 

 

 

Keypad Beep

 

 

Keypad beep enabled

 

 

 

 

 

 

 

Show Status

 

 

Display current status of doors on LCD

 

 

 

 

 

 

 

Show Events

 

 

Display events on LCD as they occur

 

 

 

 

 

 

 

Handshake

 

 

Use handshake line when printing

 

 

 

 

 

 

 

Tech Bleep2

 

 

Controller bleeps for technical fault

 

 

 

 

PIN Length

 

 

Sets the length of user/group PIN codes.

 

 

 

 

Fire Doors

 

 

Allows the definition of doors with fire override.

 

 

 

 

User Tracking2

 

 

 

 

Define Perimeter doors

 

 

 

 

 

 

Perimeter

 

 

 

 

 

 

 

 

Antipassback

 

Define Antipassback doors

 

 

 

 

 

 

 

Tracking Reset

 

Set time for auto-reset (auto-logout)

 

 

 

 

 

 

 

User Limits

 

Set user limits A & B

 

 

 

 

Outputs2

 

 

Door 1

 

Define door 1 output special functions

 

 

 

 

 

 

 

Door 2

 

Define door 2 output special functions

 

Door Settings*

 

 

 

 

 

 

 

Door release button enabled

 

 

 

Operation

 

 

Push Button

 

 

 

 

 

 

 

 

Lock Saver

 

Relay de-energized as door opens

 

 

 

 

 

 

 

Chime

 

Buzzer sounds as door opens

 

 

 

 

 

 

 

Guest Button

 

! on external keypad fires AUX/buzzer

 

 

 

 

 

 

 

Exit Always

 

Timezones don’t apply to exit readers

 

 

 

 

 

 

 

Interlock

 

Only one door may be open at any time.

 

 

 

 

 

 

 

Silent

 

Confirmation tones disabled

 

 

 

 

 

 

 

Exit PIR

 

Door stays open while Push Button closed

 

 

 

 

 

 

 

Failsafe

 

Door relay is normally energised

 

 

 

 

Alarms

 

 

 

 

Buzzer o/p active if door forced

 

 

 

 

 

 

Door Forced

 

 

 

 

 

 

 

 

Door Ajar

 

Buzzer o/p active if door left ajar

 

 

 

 

 

 

 

Duress Alarm

 

Buzzer o/p activated by duress code

 

 

 

 

 

 

 

Door Open

 

Buzzer o/p active while door open

 

 

 

 

 

 

 

Acc. Granted

 

Buzzer o/p when access granted

 

 

 

 

 

 

 

Acc. Denied

 

Buzzer o/p when access denied

1Feature present on ACT1000 only

2Feature present on ACT2000 only

*On ACT2000 you will first be required to select a door.

Page 12 of 32