Haier AC142XCERA, AC182XCERA Preparing Indoor Unit Installation, A.Floor Console Type

Models: AC142XCERA AC182XCERA

1 26
Download 26 pages 58.44 Kb
Page 11
Image 11
PREPARING INDOOR UNIT INSTALLATION

REMOVE THE INTAKE GRILL Installation Procedures

PREPARING INDOOR UNIT INSTALLATION

REMOVE THE INTAKE GRILL

Open the intake grill and remove the three or four or six screws.(Fig. 1)

Fig. 1

Intake grill

A.FLOOR CONSOLE TYPE

1.DRILLING FOR PIPING

Select piping and drain directions.(Fig.2) The piping and drain can be made in three directions as shown below.

Remark:

The main unit can be wired before the indoor unit is installed. Select the most appropriate installation order.

When the directions are selected, drill a 7 cm dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow. When the pipe is led out from the rear, make a hole in Fig.4, at the position shown.

(Fig.2)

 

(Fig.4)

 

 

 

Wall

 

 

 

 

6mm

 

rear

7cm

 

 

 

 

 

right

Indoor unit

outdoor unit

 

 

 

 

down

 

 

The drain hose can be connected to either the left or right side.(Fig.3)

When installing set to wall, install the accessory wall bracket at the position shown in Fig.5,and mount the set to it.

(Fig. 3)

(Fig. 5)

65.5cm

53cm

4.5cm

Drain hose (Left side)

Drain hose (Right side)

99cm

50cm 24.5cm

Wall bracket

A.FLOOR CONSOLE TYPE Side of set

6.5cm

 

 

7cm hole

6.5cm

3.5cm hole

 

12.5cm

10cm

 

9

Page 11
Image 11
Haier AC142XCERA, AC182XCERA Preparing Indoor Unit Installation, A.Floor Console Type, Installation Procedures