Installation Procedures
PREPARING INDOOR UNIT INSTALLATION
REMOVE THE INTAKE GRILL
Open the intake grill and remove the three or four or six screws.(Fig. 1)
Fig. 1
Intake grill
A.FLOOR CONSOLE TYPE
1.DRILLING FOR PIPING
Select piping and drain directions.(Fig.2) The piping and drain can be made in three directions as shown below.
Remark:
The main unit can be wired before the indoor unit is installed. Select the most appropriate installation order.
When the directions are selected, drill a 7 cm dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow. When the pipe is led out from the rear, make a hole in Fig.4, at the position shown.
(Fig.2) |
| (Fig.4) |
|
|
| Wall |
|
|
|
| 6mm |
| rear | 7cm |
|
|
|
| |
| right | Indoor unit | outdoor unit |
|
|
| |
| down |
|
|
The drain hose can be connected to either the left or right side.(Fig.3)
When installing set to wall, install the accessory wall bracket at the position shown in Fig.5,and mount the set to it.
(Fig. 3) | (Fig. 5) |
65.5cm | 53cm | 4.5cm |
Drain hose (Left side) | Drain hose (Right side) |
99cm
50cm 24.5cm
Wall bracket
Side of set
6.5cm |
|
|
7cm hole | 6.5cm | |
3.5cm hole |
| |
12.5cm | 10cm |
|
9