Haier HSU-10LQA13 Operation Mode COOL,DRY mode, If it is low wind, no change, COOL, DRY mode

Models: HSU-18LEK03/R2(DB) HSU-10VEK03 HSU-15LQA13 HSU-12LEK03/R2(DB) HSU-12LQA13/R2(DB)-WT HSU-09LQA13/R2(DB)-WT HSU-10LQA13 AS12GB2LAA HSU-12LQA13/R2(DB)-BK HSU-09LQA13/R2(DB)-BK AS12GS1ERA HSM24HEK03/R2(DB) AS18GS1ERA

1 8
Download 8 pages 11.85 Kb
Page 4
Image 4

Operation

Sleep Operation

Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.

Note

When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on.

Operation Mode

1. In COOL,DRY mode

1 hours after SLEEP mode starts,temp.will become 1OC

higher than temp.setting.After another 1 hours,temp.rises

by 1OC futher.The unit will run for further 6 hours then stops

Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep.

SLEEP operation starts

SLEEP operation stops

 

 

 

 

 

 

 

 

 

 

Approx.6hrs

 

 

 

 

 

 

 

 

 

1 hr

 

Rises 1OC

 

 

1 hr

Rises 1OC

 

 

 

 

 

 

 

 

 

 

 

 

Temp.setting

 

 

Unit stop

In COOL, DRY mode

2. In AUTO mode

The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.

3.In FAN mode

It has no SLEEP function.

4.Set the wind speed change when sleeping

If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.

If it is low wind, no change.

TURBO/QUIET Operation

TURBO/QUIET

TURBO/QUIET

When you need fast cool or fast dehumidification,you can

choose the Turob function; when you sleep, read, you can

choose Quiet function

Press the TURBO/QUIET buon, you can switch the “Turbo” and “Quiet”

will swith as below

TURBOQUIET cancel

When running in Turbothe fan speed is the highest,

when running in Quiet, the fan speed is super slow

HEALTH Operation

Nano-Aqua generator adopt two high voltage pole to ionize the water molecule into nanometer water ion,and release these ions to the air to kill the bacterium and refresh the air. as well as the nanometer water inon can be easily absorbed by skin,keeping moisture anytime.