Haier HSM24HEK03/R2(DB), AS18GS1ERA Base Operation Emergency operation and test operation

Models: HSU-18LEK03/R2(DB) HSU-10VEK03 HSU-15LQA13 HSU-12LEK03/R2(DB) HSU-12LQA13/R2(DB)-WT HSU-09LQA13/R2(DB)-WT HSU-10LQA13 AS12GB2LAA HSU-12LQA13/R2(DB)-BK HSU-09LQA13/R2(DB)-BK AS12GS1ERA HSM24HEK03/R2(DB) AS18GS1ERA

1 8
Download 8 pages 11.85 Kb
Page 3
Image 3

Operation

Base Operation

Emergency operation and test operation

Emergency Operation:

Remote controller

2

TURBO/QUIET

 

 

 

 

 

 

11

 

 

 

3

SWING

 

 

4

 

 

 

 

 

3

2

HEALTH

SLEEP

 

TIME

TIME

 

 

ON

OFF

 

 

Use this operation only when the remote controller is defective

or lost, and with function of emergency running, air conditoner

can run automatically for a while.

 

When the emergency operation switch is pressed, the " Pi "

sound is heard once, which means the start of this operation.

When power switch is turning on for the first time and

emergency operation starts, the unit will run automatically in

the following modes:

 

 

Pi

Room

Designated

Timer

Fan

Operation

temperature

temperature

mode

speed

mode

Above 23oC

26oC

No

AUTO

COOL

It is impossible to change the settings of temp. and fan speed,It

1. Unit start

Press ON/OFF on the remote controller, unit starts.

2.Select operation mode

COOL button:Cooling mode FAN button: Faning mode DRY button: Dehumidify mode

3.Select temp.setting

Press

/

button

 

Every time the button is pressed, temp.setting

 

increase 1oC,if kept depressed, it will increase

 

rapidly

 

 

Every time the button is pressed, temp.setting

 

decrease 1oC,if kept depressed, it will

 

decrease

rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

Display circulated

LOW MED

HI

AUTO

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

Operation

Remote

Note

Mode

Controller

 

 

 

Under the mode of auto operation, air conditioner will

AUTO

 

automatically select Cool or Heat operation according to

 

room temperature. When FAN is set to AUTO the air

 

 

conditioner automatically adjusts the fan speed according

 

 

to room temperature.

COOL

 

according to room temperature.

DRY

 

In DRY mode , when room temperature becomes lower

 

than temp.setting+2o C, unit will run intermittently at LOW

 

 

speed regardless of FAN setting.

 

 

In FAN operation mode , the unit will not operate in COOL or

FAN

 

HEAT mode but only in FAN mode, AUTO is not available in

 

FAN mode. And temp. setting is disabled. In FAN mode,

 

 

sleep operation is not available.

is also not possible to operate in timer or dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room

temperature is below 16oC, do not use it in the

normal operation.

Pi Pi

 

Continue to press the test operation

switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor unit will run in high speed.

Air Flow Direction Adjustment

1.Status display of air flow

Vertical flap

Pos.1

(Auto swing)

Initial state

Pos.2 No initial state disaplayed on remote controller, the vertical flap will be fixed on the current position

2.Left and right air flow adjustment

For each press of button, remote controller displays as follows :

remote controller:

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

 

 

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur adjusted to left or at air outlet if all vertical louvers are right.

It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.

Note:

When restart after remote turning off, the remote controller controller will automatically memorize the previous set swing position.

3

Page 3
Image 3
Haier HSM24HEK03/R2(DB) Base Operation Emergency operation and test operation, Air Flow Direction Adjustment