 INSTALLATION MANUAL FOR WIRE CONTROLLER

1.Remove the upper cover of wire controller INSTALLATION MANUAL FOR WIRE CONTROLLER

1.Remove the upper cover of wire controller

The PC board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage PC board.

Upper cover of wire controller

 

HEALTH

C

 

F

SET RECOVERY

CHECK

Back cover of wire controller

2.Install wire controller

**Drill 2 wall holes according to the position of the 2 screw holes on the back *cover of wire controller, then hit wood in the wall holes. Put the 2 screw holes *on the back cover of wire controller properly to its corresponding wood, then *use wood screws to fix the back cover on the wall.

Note:

Install the back cover of wire controller on the even wall as possible as can. When tightening the wood screw, do not use to tight force, otherwise the wire controller may be damaged.

Note:

When connecting wire, please keep a certain distance between signal wire and electric wire. (over 10mm)

Dimension of signal wire:

Type of wire Shield wire (4 cords)

Dimension 0.33mm2

3.Indoor unit wire connection

Connect the terminals (A, B, C, D,) on the wire The connection between indoor unit

controller to the terminals on the indoor PC

and wire controller and indoor unit

and outdoor unit should use shield

panel (A, B, C, D,) respectively.

 

 

 

 

wire. And the two ends of the shield

 

 

 

 

 

Arrange wire from this part

 

 

 

wire

should be

grounded,

AB

CD

 

 

 

otherwise, the disturbance will

 

Back cover

 

 

 

cause unit abnormal operation.

HEALTH

 

HEALTH

 

 

 

 

FC

SET RECOVERYwire controller

FC

SET RECOVERY

Upper cover

Shield wire

CHECK

 

 

CHECK

of wire

 

 

 

 

 

controller

Grounded

Grounded

Note:

Confirm the connection part of terminals is firm and will not touch shield wire.

4.Cover the wire controller upper cover

Pay attention not to press the connection wire.

Note: Do not touch PC board by hand.