Haier HDU-09HA03/M(R1)(B), AU092AABHA Installation Manual For Electric Wiring, Electric wiring

Models: HDU-12HA03/M(R1)(B) HDU-09HA03/M(R1)(B) AD092AMBHA AD122AMBHA AU122AABHA AU092AABHA

1 24
Download 24 pages 20.6 Kb
Page 22
Image 22
 INSTALLATION MANUAL FOR ELECTRIC WIRING

5. Electric wiring INSTALLATION MANUAL FOR ELECTRIC WIRING

5. Electric wiring

Cautions: Use copper wire only.Parameters of connecting

line : H05RN-F 4G0.75mm2

Power supply :1PH,220-230V~,50Hz, connect from outside.

Wiring methods:

1.Wiring method of ring terminal

For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw.

2. Wiring method of straight terminal

For connecting line which end is not a ring, its wiring method as follows: loosen wiring screw ans insert the end of connecting line totally into the terminal block,then tighten the screw and pull the connecting line slightly to confirm that it is clamped firmly.

Crimp connection method of connecting line

Wiring method of ring terminal

Correct crimp

Incorrect crimp

connection of wire

connection of wire

Terminal block

Crimp connection

clamp

 

After finishing wiring.connecting line must be fastened by wire clamp,which pressed on the external sheath of the connecting line, as shown in the right figure:

Wiring of indoor unit

Indoor unit terminal block Open air inlet grill

Outdoor unit terminal block Take the leading end of connecting line

to power supply Connect connecting line according to wiring methods and wiring diagram of indoor and outdoor unit

Manual background Fasten connecting line according to crimp connection method of connecting line.

Manual background Reinstall air inlet grill.

1

2

3

1

2

3

Indoor unit terminal block

Outdoor unit terminal block

1.Installation fixing

Fix outdoor unit installation bracket on the wall using a

M10 anchor bolt.Fix outdoor unit on the installation bracket firmly using bot(M10) and nut, and keep it on horizontal level. When installing on the wall or on the roof ,fix the bracket, firmly to prevent earthquake or storm.

Be sure to use rubber-damping cushion to reduce unit vibration.

2.Installation of drain elbow

Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure.

Do not use drain elbow in cold place (temperature successively below 0Manual backgroundC)

to power supply

Terminal

Wire clamp

Power supply

Connecting wire between inner and outer

3. Connection of outdoor piping

Connect the connecting pipe according to the piping connection method

4.Wiring connection

1.Open the wiring cover and loosen the wiring clamp.

2.Lead the connecting wire out and pass it through the wiring clamp.

3.Connect the connecting wire according to the wiring method and diagram

4.Confirm the ends of wire are connected well, safe and correct.

5.After finishing wiring, press the connecting wire according to the wire crimp connection method and reinstall the cover.

1

2

3

21

Page 22
Image 22
Haier HDU-09HA03/M(R1)(B), AU092AABHA Installation Manual For Electric Wiring, Electric wiring, Indoor unit terminal block