2
6
Localizethe Installation:
Installthe indoor unit where the weight of the unit can be supported.
Installthe indoor unit where the head source and steam source are not close and the unit inlet and
outletare not blocked.
Installthe indoorunit wherethe drainage is easy and the outdoor unit can easily connected.
Installthe indoor unit where its cold air and hot air canbe easily sent to all the corners of the room.
Installthe indoor unit where the power socket is nearand there is sufficient space around the indoor
unit.
Installthe indoor unit where there is no T.V set, radio set, and wireless appliance underneath, and the
sunlightlamp is over one meter away.
Ifthe remote controller is installed on the wall, the indoor unit shallbe ensured to receive the signal
whilethe sunlight lamp is on.
Thelocation shall bear the weight of the unit and will not produce a big vibration and noise.
Thelocation shall be in good ventilation,and the airflow blew out and noise produced shall not affect
theneighbors.
Thelocation shall not be directly drenched in rain,sun,or blew by sea wind.
Thelocation shall not be near anywhere the corrosive gas(SO ),flammablegas(thinner or gasoline),oil
mist,orsteam are probably produced(for example in kitchen).
Sufficientspace shall be left for air inlet and outlet.
Thelocation shall be easily maintained and repaired.
Itcannot be installed on a non-professional metal structure(like anti-burglary net).
2
IndoorUnit
OutdoorUnit
Methodfor Cutting and Expanding Pipes:
PipingConnection
Whenthe pipe is too long or its mouth is damaged,the pipe needs to cut or expand.
1. Connecting Method
Toensure the efficiency,the pipe should be as short as
possible.
Applyrefrigerant oil at half union and flare nut.
Tobend a pipe,five the roundness as large as possible
notto crash the pipe.
Whenconnecting pipe,hold the pipe center to center
thenscrew nut on by hand,refer to the Drawing.
Becareful not to let foreign matters,such as sands enter
thepipe.
Liquidhose
Gashose
ExpansionSize
Hosedia.
6.35mm(1/4")
9.52mm(3/8")
12.7mm(1/2")
Size(mm)
0.8-1.5
1.0-1.8
1.2-2.0
Pipedia. Recommended
FasteningTorque
18N.m
42N.m
50N.m
Liquidpipe 6.35mm(1/4")
GasPipe 9.52mm(3/8")
GasPipe 12.7mm(1/2")
Correct
NotCorrect
Tilting burr incomplete toolong
crackson
expanded
mouth
SpannerSpannerRefrigeration OilConnector NutAHose Expander1.Cutting hose3.Put on nut2.Removing burr4.Expand Hose
Installat
i
on
RemoteController ,s Operation
Loadingof Batteries
RemoveBattery Cover:
Whenin use, point thesignal sending head directly to the receiver window on the indoor unit.
Thedistance between the signal sending head and the receiver window shouldbe within 7 m
withoutany obstacle as well.
Don'tthrow the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp orchange-over type fluorescent lamp or
wirelesstelephone is installed in the room, the receiver is apt to be disturbed in receiving the
signalsso the distance to the indoor unit should be shorter.
Loadthe batteries as illustrated in the drawing below:
Slightlypress andpush down the cover. Then, as the drawing, holdthe upper end of
theremote controller with left hand, and slightly hold the cover with right hand, push slightly in
thearrow direction to remove the battery cover .
Besure that the loading is in line with the + / - asillustrated.
Putback the cover inthe reverse procedure.
Ifthere is no display after pressing the on/off button, reload the batteries.
Notes:Use two same-typed batteries when loading.
If the remote controller cannot run normally or doesn't work at all, use a sharp pointed
itemto press the reset button (with the mark ).
LoadBatteries:
Putback Cover:
ConfirmationIndicator:
7
Operat
i
on