For the purpose of safety, the air
conditioner mustbe properly grounded in
accordancewith specifications.
Specifications
Therefrigerating circuit is leak-proof.
Always remember to unplug air
conditionerbefore opening inlet grill. Never
unplugyour air conditioner by pulling on the
powercord.Always grip plug firmly and pull
straightout from the outlet.
Allelectrical repairs must be carriedout
by qualified electricians.Inadequate repairs
mayresult in a major source of danger for
theuser of the air conditioner.
Do not damage any parts of the air
conditionerthat carry refrigerant by piercing
or perforating the air conditioner's tubes with
sharpor pointed items, crushing or twisting
anytubes, or scraping the coatings off the
surfaces.If the refrigerant spurts out and
gets into eyes,it mayresult in serious eye
injuries.
Do not obstruct or cover the ventilation
grilleof the air conditioner.Do not put fingers
or any other things intothe inlet/outletand
swinglouver.
Donot allow children to play with the air
conditioner.In no case should children be
allowedto sit on the outdoor unit.
Themachine is adaptive in following situation
1.Applicableambient temperature range:
2.Ifthe supply cord is damaged, it must be replaced
bythe manufacturer or its service agent or a similar
qualifiedperson. The type of connectingwire is
H05RN-For H07RN-F:3G1.5mm +1X0.75mm..
3.Ifthe fuse on PC board is broken please change it
withthe type of T.3.15A/250V.If the fuse of outdoor
uitis broken please change it with the type
ofT.25A.AC250V.
4.Thedistance between the indoor unit and the floor
shouldbe more than 2m.
5.Thewiring method should be in line with the local
wiringstandard.
6.Afterinstallation ,the power plug should be easily
reached.
7.Thewaste battery should be disposed properly.
8.Theappliance is not intended for use by young
childrenor infirm persons without supervision.
9.Youngchildren should be supervised to ensure
thatthey do not play with the appliance.
10.The requirement of power supply cord.
22
Cooling
Heating
Indoor
Indoor
Outdoor
Outdoor
32 /23
Maximum:D.B/W.B
Maximum:D.B/W.B
24 /18
18 /14
Minimum:D.B/W.B
Minimum:D.B/W.B
-7 /-8
15
20
43
Minimum:D.B
Maximum:D.B
Minimum:D.B
Maximum:D.B
27
Caut
i
ons
Series
European
region
10 12
H05VV-F
3G1.5mm2
H05VV-F
3G1.5mm2
Installat
i
on Check and Tr
i
al Operat
i
on
Pleaseoperate the air conditioner in accordance with this Operation Manual
Checkitems for the Trial Operation(Tick in )
Isthe connector leaked?
Howis the connector insulated?
Isthe electric connection between the indoor and outdoor units firmly inserted into the
terminalplate?
Arethe electric wires on the indoor and outdoor units fixed firmly?
Isthe drain pipe placed correctly?
Isthe earth line connected firmly?
Doesthe power supply voltage conform to the electric regulations?
Isthere any noise?
Isthe cooling operation normal?
Isthe indoor temperature adjuster working normally?
PowerSupply:
L shouldbe connected with the live wire;
Nshould be connected with the zero wire;
shouldbe connected with the earth wire.