Wiringfor Indoor and Outdoor Units
1.Wiring Method for Ring Terminal
Thewiring method is as the drawing below for the ring terminal:
Remove the connection screw and put the screw through the ring on
the connection wire terminal, thenconnect itto the terminal blocks,
thenscrew it tightly.
2.WiringMethod for Line Terminal
Thewiring method is as follows for the non-ring terminal:
Loosenthe connection screw and insert the connection wire end into the
terminal block completely,screw it tightly, then slightly pull outthe
connectionwire to ensure it be clamped tightly.
3.Method for Pressing the Connection Wire
Afterwiring, the connection wire must bepressed tightly with a wire-
pressing clip, which should press the outer sleevesof the wire as the
rightdrawing:
Wiringfor Indoor Unit and Outdoor Unit
Layout the connection wires as the connection drawing (Notes: The two ends of the connection
wiresare different, never connect reversely)
1)Open the wire cover, unscrew the pressing clamp(outdoor unit).
2)Connect the connection wires as per the wiring method and the wiring drawing (the wireson
theindoor unit shall be inserted from behind as the attached drawing).
3)Ensure that the terminals are clamped tightly, and press the connection wires(outdoor unit) as
perthe pressing method, then install the wire-pressing cover.
Notes:
Whenconnecting the wires of indoor and outdoor units, check the numbers on the terminals
ofthe indoorand outdoorunits,the same wire shall connect the same number and color
terminal
Wrongconnection would damage the air conditioner,s controller,or the unit cannot work.
AirInlet Grille
PressingCover
Screw
Terminals
PressingClamp
PowerSupply Wire
Indoorand Outdoor
Connecion Wirest
CorrectPressing Wrong Pressing
Terminal
block
Pressing
Clamps
WiringMethod for
RingTerminal Block
Installat
i
on Name of Parts
IndoorUnit:
OutdoorUnit:
1. InletGrill
2. AnionGenerator (inside)
3. AirFilter
4. Swinglouver
Itcan be adjusted to upward or downward with the remotecontroller only (Do not adjust it manually)
5. Poweror Healthy Operation Indicator
Afterthe air conditioner is started, this indicator lights up; when the healthy operation is started,this
indicatorturns green.
6. TimerSet Indicator
Whenthe air conditioner is at the state of time-set, this indicator lights up.
7. Test
Thisbutton is only used for test refrigerating operation when the room temperature is below 16 ,so it
shouldnot be used in normal situation.
8. EmergencyManual Button
Whenthe remote controller is lost or cannot be used, this button can make the air conditioner continue
tooperate for the time being.
9. RemoteSignal Receiving Window
Itreceives the remote signal from the remote controller.
10.Working Method Indicator
Whenthe compressor is working, the indicator lights up .
11. Power Plug
ManualButton
1.Inlet
2.Outlet
Sendout hot air when cooling,
andsend out cold air when heating .
3.Inlet
4.Connection pipe and electric wiring.
5.Drain Hose
1
1
2
2
3
4
4
5
6
5
7
8
9
10
11
3
3