Haier AU422BIBAA, 0010571564 Installation instruction, Installation tools, Install and fix

Models: 0010571564 AU422BIBAA

1 16
Download 16 pages 44.86 Kb
Page 6
Image 6
Installation instruction

Installation instruction

Installation tools

1.Screwdriver

2. Steel saw

3. Pipe cutter

4. Pipe flarer

5.Knife 6. 70mm diameter drill

7.Leakage detector/soap water

8.Spanner (diameter 17,27mm)

9.Spanner (14, 17, 19, 27mm)

10. Pincers

11. Tape measure

12. Scraper

13. Refrigerant oil

14.Vacuum pump

15. Nitrogen tank

Install and fix

The following is the manual mentioned standard accessories, please check them by yourself.

Name

Shape Amount

Putty

1

Rubber cushion

4

Refrigerant oil

1

Plastic clamp

6

Manual

1

Installation tools Use screw bolt (M10) and screw nut to tightly fix the outdoor unit on its bracket, and keep it level.

Install and fix When install on the wall or roof, fix the bracket firmly and reliably to prevent from the attack of earthquake or strong wind.

Connection of pipe In order to lower the vibration, the rubber cushion must be installed. 1. Connection method of pipe The installation slant degree of the unit should be less than 3*.

Standard accessories (self-provided installation parts)

Mark

A

B

C

D

E

F

Name of Adhesive Pipe supporting Connection Drain hose Thermal insulation Plaster powder

parts

tape

plate

hose

 

material

 

 

 

 

 

 

 

380

Connection of pipe

 

190

580

190

 

Installation dimension of outdoor unit (mm)

Manual background Warning

Manual background During installation, if the refrigerant leaks, please immediately take ventilation measure.

Manual background Once the leaked refrigerant gas meet fire, poisonous gas will be generated. Manual background After finishing installation, make sure the refrigerant gas will not lead.

1. Connection method of pipe

(1)The joint of refrigerant connection pipe is at the right side of the outdoor unit. (2)The connection pipe can be connected out from the right side of outdoor unit.

Manual background For single system, the max length of connection pipe is 15m and the max fall is 5m.

Manual background In order to guarantee efficiency, the connection pipe should as short as possible. Manual background Daub the refrigerant oil on the joint and flare.