Air Conditioner | Edition:2006/1/10 | |
|
|
|
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
7.The appliance is not intended for use by young children or infirm persons without supervision.
8.Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1.Applicable ambient temperature range:
| Indoor | Maximum:D.B/W.B | 32oC/23oC | |
| Minimum:D.B/W.B | 18oC/14oC | ||
Cooling |
|
|
| |
Outdoor | Maximum:D.B/W.B | 43oC/26oC | ||
| Maximum:D.B | 18oC | ||
| Indoor | Maximum:D.B | 27oC | |
| Maximum:D.B | 15oC | ||
Heating |
| |||
Outdoor | Maximum:D.B/W.B | 24oC/18oC | ||
| ||||
| Minimum:D.B/W.B | |||
|
|
2.If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3.If the fuse of indoor unit on PC board is broken,please change it with the type of
T.3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V
4.The wiring method should be in line with the local wiring standard.
5.After installation, the power plug should be easily reached.
6.The waste battery should be disposed properly.
10 .The power plug and connecting cable must have acquired the local attestation.
11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.