LocationRequirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The location should provide:

ʄGrounded electrical outlet within 6 ft (183 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord.

ʄFree movement of air in room to be cooled.

ʄA large enough opening for the air conditioner. Installation parts are supplied for double-hung windows.

ʄAdequate wall support for weight of air conditioner. Air conditioner weighs 40 lbs to 46 lbs (18.1 kg to 20.9 kg).

NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

A

ElectricalRequirements

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located either on the side or back of the air conditioner cabinet or behind the front grille.

6SHFL¿FHOHFWULFDOUHTXLUHPHQWVDUHOLVWHGLQWKHFKDUWEHORZ Follow the requirements for the type of plug on the power supply cord.

A. Cabinet louvers

Window Installation

Window opening measurements:

ʄ22” minimum to 36” (55.9 cm to 91.4 cm) maximum opening width.

ʄ133⁄8” (34 cm) minimum opening height.

A

B

A. 22” (55.9 cm) minimum

B. 133⁄8” (34 cm) minimum

Power Supply

 

Cord

Wiring Requirements

ʄ115-volt (103.5 min. to 126.5 max.)

ʄ 0 to 12 amps

ʄ15-amp time-delay fuse or circuit breaker

ʄUse on single outlet circuit only.

Recommended Grounding Method

This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed E\DTXDOL¿HGHOHFWULFDOLQVWDOOHU

It is the customer’s responsibility:

7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU

4

Page 4
Image 4
Haier ESA405K manual LocationRequirements, ElectricalRequirements, Window Installation, Power Supply Cord