3.SPECIFICATION

D

3.SPECIFICATION

Figure 1

W

H

The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 1 for 13 SEER systems respectively.

The Figure 2 show a schematic of the cooling only system.

Table 1: Model:HC18-42D2VAR

MODEL:

 

HC18D2VAR

HC24D2VAR

HC30D2VAR

HC36D2VAR

 

HC42D2VAR

Unit Supply Voltage

 

 

208/230 60Hz 1PH

 

 

 

Normal Voltage Range

 

 

197 - 253

 

 

 

Compressor Brand

 

 

Bristol

 

 

 

Minimum Circuit Amps

7.6

10.9

14.0

16.4

 

18.1

Max Fuse or Max CKT. BKR.

 

 

 

 

 

 

(HACR per NEC )

15

20

25

30

 

30

 

Rated Load Amps

5.4

8.0

10.1

11.8

 

13.2

Compressor

Locked Running

 

 

 

 

 

 

 

Amps

36.0

53.5

61.0

78.0

 

78.0

 

 

 

 

 

 

 

 

 

Full Load Amps

0.86

0.86

1.4

1.6

 

1.6

 

 

 

 

 

 

 

 

Fan Motor

Rated HP

1/8

1/8

1/4

1/3

 

1/3

 

Nominal RPM

1000

1000

1075

1120

 

1120

Liquid Line OD - In (mm)

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

 

3/8" [9.52]

 

 

 

 

 

 

 

 

Vapor Line OD - In (mm)

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

7/8"[22.2]

 

7/8"[22.2]

 

 

 

 

 

 

 

 

R-22 Charge -Oz (g)

84.81[2400]

84.81[2400]

123.67[3500]

137.81[3900]

 

141.34[4000]

 

 

 

 

 

 

 

 

Net Dimensions - In (mm)

21 1/2"*21 1/2"*23 3/8"

21 1/2"*21 1/2"*26 7/8"

24 1/4"*24 1/4"*23 3/8"

241/4"*24 1/4"*26 7/8"

 

24 1/4"*24 1/4"*30 3/8"

W*D*H

 

[547* 547*595]

[547* 547*683]

[616* 616*595]

[616 *616*683]

 

[616 *616*771]

 

 

 

 

 

 

 

 

Shipping Dimensions - In (mm)

23" *23" *25 "

23"*23"*28 1/2"

26 7/8"*26 7/8"*25"

26 7/8"*26 7/8"*28 1/2"

 

26 7/8"*26 7/8"*32"

W*D*H

 

[585* 585*637]

[585* 585*725]

[ 682* 682*637]

[682*682*725]

 

[682*682*813]

 

 

 

 

 

 

 

 

Net Weight - Lbs (kg)

143[65]

150[68]

176[80]

187[85]

 

198[90]

 

 

 

 

 

 

 

 

Approx Shipping Weight - Lbs (kg)

158[72]

165[75]

192[87]

202[92]

 

214[97]

 

 

 

 

 

 

 

 

Table 2:System Cooling Capacity

Cooling

 

 

Indoorfan

 

ARI data of indoor

Cooling Capacity with different outdoortemperature

 

 

 

 

 

Outdoor

Indoor

speed

 

Capacity

SEER

CFM

80

85

90

95

100

105

110

115

HC18D2VAR

HB2400VD1M20

M

 

17000

13

670

19210

18649

18020

17000

16745

16490

16235

15980

HC24D2VAR

HB2400VD1M20

H

 

23000

13

900

25990

25231

24380

23000

22655

22310

21965

21620

HC30D2VAR

HB3600VD1M22

L

 

29000

13

1125

32770

31813

30740

29000

28565

28130

27695

27260

HC36D2VAR

HB3600VD1M22

H

 

35000

13

1240

39550

38395

37100

35000

34475

33950

33425

32900

HC42D2VAR

HB4800VD1M22

L

 

41000

13

1480

46330

44977

43460

41000

40385

39770

39155

38540

2