1.Fully open both shutoff valves.

2.Connect service gage manifold to the valve service ports, being sure to evacuate lines.

3.Startup the system (Refer to the Section 7 - "System Startup"). Run system at least 10 minutes to allo pressure to stabilize.

4.Temporarily install thermometer on suction (large) line near condensing unit. Be sure of good contact between thermometer and line. Wrap thermometer with insulating material to assure accurate reading.

5.Refer to Table 5 for proper system superheat. Add charge to lower superheat. Remove charge to raise superheat.

Carefully remove gage lines.

System Superheat

Ambient

 

 

Return Air Temperature ( F)

Temperature At

 

 

 

 

 

 

 

 

 

65

70

75

80

85

Condenser Inlet (

F)

 

 

 

 

 

60

 

 

17

25

30

33

37

65

 

 

13

19

26

32

35

70

 

 

5

14

20

28

32

75

 

 

5

10

17

25

29

80

 

 

 

5

12

21

26

85

 

 

 

5

10

17

20

90

 

 

 

 

7

12

18

95

 

 

 

 

5

5

5

100

 

 

 

 

 

5

5

Table 5:System charging table by superheat

6.4.ELECTRICAL WIRING

! WARNING -

A means of strain relief must be installed to this appliance at the electrical service entrance. Make sure that interconnecting wires between indoor and outdoor units meet the standards, codes and regulations. Incomplete connection or fixing of the wire could result in a fire.

A means of strain relief must be installed to this appliance at the electrical service entrance. Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet. It could cause a fire or an electric shock due to defective contact, defective insulation, exceeding the permissible current, etc.

Perform electrical work according to the installation manual and be sure to use an exclusive circuit. If the capacity of the power circuit is insufficient or there is incomplete electrical work, it could result in a fire or an electric shock.

Ground the unit. Do not connect the ground to a gas pipe, water pipe, lighting rod or telephone ground. Defective grounding could cause an electric shock.

Electrical installation will consists of power supply wiring to the condensing unit and control wiring between thermostat, indoor unit and the condensing unit. All wiring must be in accordance with National Electrical Code and/or local ordinances that may apply.

(See unit wiring diagram furnished with this instruction).

Note: Some states need the power supply wiring within special tybe be careful to use the waterproof tube when installation the outdoor unit power supply wiring.(See the Figure 5)

Figure 5-1

Figure 5-2

10

Page 12
Image 12
Haier HC30D2VAR, HC42D2VAR, HC36D2VAR, HC24D2VAR, HC18D2VAR operation manual Electrical Wiring

HC18D2VAR, HC24D2VAR, HC30D2VAR, HC36D2VAR, HC42D2VAR specifications

Haier has long been a name synonymous with innovative home appliances, and their line of high-efficiency mini-split air conditioning systems exemplifies this tradition of excellence. Among the standout models are the HC18D2VAR, HC24D2VAR, HC30D2VAR, HC36D2VAR, and HC42D2VAR. Each of these units brings unique features tailored to meet diverse cooling needs while emphasizing efficiency, comfort, and usability.

The HC18D2VAR is designed for smaller spaces, affording homeowners effective cooling without breaking the bank on energy costs. It features variable refrigerant flow technology, allowing the system to adjust its capacity based on the current temperature and cooling load. This ensures optimal energy use while maintaining a consistent indoor environment. The built-in inverter technology further enhances efficiency, reducing energy consumption compared to traditional systems.

Moving to the HC24D2VAR, this model expands its capabilities, making it suitable for medium-sized rooms or offices. It boasts a sleek design that allows for discreet installation, while the advanced air filtration system effectively captures dust, pollen, and other allergens, enhancing indoor air quality. Additionally, its quiet operation ensures minimal disruption, making it ideal for bedrooms and study areas.

The HC30D2VAR is tailored for slightly larger applications, with superior cooling and heating performance. This model incorporates smart technologies such as Wi-Fi connectivity, enabling users to control their air conditioning remotely via a smartphone app. It also featuresmultiple airflow settings and a programmable timer that provides convenience for busy lifestyles.

For those needing even more cooling power, the HC36D2VAR and HC42D2VAR models are designed to handle larger spaces while maintaining energy efficiency. These units come equipped with advanced cooling technologies, including turbo cooling mode for quick temperature adjustment, and an extended range of operating temperatures, ensuring reliable performance in varying climates. The sleek aesthetic of these models blends seamlessly with modern interior designs.

All five models are equipped with user-friendly interfaces and remote control options, simplifying the adjustment of settings distance. With their high Seasonal Energy Efficiency Ratios (SEER), these Haier units provide a balance of comfort and efficiency, making them an excellent choice for homeowners looking to enhance their living environment while being environmentally conscious.

Overall, the Haier HC18D2VAR, HC24D2VAR, HC30D2VAR, HC36D2VAR, and HC42D2VAR models present a comprehensive solution for modern cooling needs, combining technology, efficiency, and design into one impressive package.