Haier HDU-42HT03/H Installation Manual For Indoor Unit, Serious injury are listed

Models: HDU-42HT03/H

1 34
Download 34 pages 11.56 Kb
Page 24
Image 24

Installation Manual For Indoor Unit

1. Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,

WARNING

and CAUTION , those points which are related to the strong possibility of an installation done in error

 

 

 

 

 

 

resulting in death or

serious injury are listed in the

WARNING

section. However, there is also a

possibility of serious consequences in relationship to the points listed in

the

 

section as well.

CAUTION

In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

23

Page 24
Image 24
Haier HDU-42HT03/H installation manual Installation Manual For Indoor Unit, Serious injury are listed

HDU-42HT03/H specifications

The Haier HDU-42HT03/H is a cutting-edge heating, ventilation, and air conditioning (HVAC) solution designed to provide comfort and efficiency for residential and commercial spaces. This model stands out due to its innovative features, advanced technologies, and reliable performance.

One of the key features of the Haier HDU-42HT03/H is its impressive cooling and heating capacity. With a nominal cooling capacity of 4.2 kW and a heating capacity of 5.0 kW, this model is suitable for medium-sized rooms, ensuring that spaces remain comfortable regardless of outdoor temperatures. Its Inverter technology allows for precise control of the compressor speed, resulting in faster cooling and heating, less energy consumption, and quieter operation.

The unit’s energy efficiency is highlighted by its high SEER (Seasonal Energy Efficiency Ratio) and SCOP (Seasonal Coefficient of Performance) ratings, which contribute to lower electricity bills and reduced environmental impact. The HDU-42HT03/H also features a programmable thermostat, allowing users to set specific heating and cooling schedules, optimizing energy use while maintaining comfort.

For enhanced air quality, the Haier HDU-42HT03/H comes equipped with a multi-stage filtration system that effectively captures dust, allergens, and other airborne particles. This ensures that the air circulated within the space is clean and healthy, making it an excellent choice for individuals with allergies or respiratory issues.

Additional technological advancements in the HDU-42HT03/H include the use of eco-friendly refrigerant, which minimizes its impact on the environment. The model also integrates smart technology, allowing for remote operation via a smartphone application. This feature enables users to control the unit from anywhere, providing added convenience and flexibility.

In terms of design, the Haier HDU-42HT03/H is sleek and modern, allowing it to blend seamlessly into various interior styles. Its compact structure makes it suitable for a variety of installation environments, whether in homes or businesses.

Overall, the Haier HDU-42HT03/H is a top-tier HVAC solution, boasting powerful performance, energy efficiency, and user-friendly features. It is an excellent choice for anyone looking to enhance their indoor climate control with a reliable and effective system.