Haier HPU-90CA03T3 When Troubles Occur ?, In Cooling or Dehumidifying operation, there is

Models: HPU-90CA03T3

1 32
Download 32 pages 48.03 Kb
Page 13
Image 13
When Troubles Occur ?

When Troubles Occur ?

Find the following troubles occur, please stop the unit and cut off power, then contact the after-sales service worker.

The fuse and creepage breaker are often blown out; Warning

If finding any abnormal phenomena (e.g. smell of burnt), please cut off power and ask help for after-sales

service personnel.

If still use the air conditioner under this condition, the unit may be damaged and maybe cause electric shock or fire, etc. accidents.

Symptom

After taking the following measure,

please contact the commissioned

 

service center.

 

 

The fuse and creepage breaker are often blown out;

Cut off power

or the operation switch works abnormally.

 

 

 

In Cooling or Dehumidifying operation, there is

Cut off power and inform your

water leakage;

commissioned service center.

 

 

Malfunction

Error display

 

Failure description

Code on wired controller

 

Room temp. sensor abnormal

E1

 

 

 

 

Indoor coil temp. sensor abnormal

E2

 

 

 

 

Outdoor temp. sensor abnormal

E3

 

 

 

 

Outdoor coil temp. sensor abnormal or compressor discharge

E4

 

temperature protection abnormal

 

 

 

 

 

 

Over-current malfunction

E5

 

 

 

 

High / Low pressureabnormal

E6

 

 

 

 

Communication malfunction between indoor PCB and wired controller

E8

 

Communication malfunction between indoor PCB and outdoor PCB

E9

 

The float switch malfunction

E0