Haier HPU-90CA03T3 operation manual Others

Models: HPU-90CA03T3

1 32
Download 32 pages 48.03 Kb
Page 28
Image 28
 Others

Manual backgroundManual background Others

1. Power supply

The parameter of power cord is over 2.5mm2.

Manual background Air conditioner must use an exclusive line (over 30A)

Manual background When installation air conditioner in a wet place, try to use a circuit breaker against Current leakage.

Manual background For installation in other places, use circuit breaker as far as possible.

Manual background The breaker of the air conditioner should be all-pole switch ; and the distance between its two contacts should be no less 3 mm.

Manual background Such means for disconnection must be incorporation in the fixed wiring

2. Pipe cutting and flaring

Manual background Be sure to carry out deburring after pipe cutting with a pipe cutter. Manual background Insert flaring tool to make a flare.

AFlaring tool

 

Pipe dia.

Dimension A(mm)

 

 

 

Liquid pipe

12.7mm (1/2")

1.2 ~ 2.0

 

 

 

Correct

Incorrect

Lean Damaged flare Crack

Partial Too outside

Installation inspection and test run:

Please operate unit according to this Manual.

Items to be checked during test run. Please made a " "in " "

Are there any gas leakage?

How is insulation at piping connection carried out?

Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electric wiring of indoor and outdoor securely fixed?

Is drainage securely carried out?

Is earth line ( grounding ) securely connected? Is power supply voltage abided by the code? Is there any noise?

Is control display normal? Is cooling operation normal?

Is room temp. regulator normal?

27

Page 28
Image 28
Haier HPU-90CA03T3 operation manual Others