Others

1. Power supply

The parameter of power cord is over 2.5mm2.

Air conditioner must use an exclusive line (over 30A)

When installation air conditioner in a wet place, try to use a circuit breaker against Current leakage.

For installation in other places, use circuit breaker as far as possible.

The breaker of the air conditioner should be all-pole switch ; and the distance between its two contacts should be no less 3 mm.

Such means for disconnection must be incorporation in the fixed wiring

2. Pipe cutting and flaring

Be sure to carry out deburring after pipe cutting with a pipe cutter. Insert flaring tool to make a flare.

AFlaring tool

 

Pipe dia.

Dimension A(mm)

 

 

 

Liquid pipe

12.7mm (1/2")

1.2 ~ 2.0

 

 

 

Correct

Incorrect

Lean Damaged flare Crack

Partial Too outside

Installation inspection and test run:

Please operate unit according to this Manual.

Items to be checked during test run. Please made a " "in " "

Are there any gas leakage?

How is insulation at piping connection carried out?

Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electric wiring of indoor and outdoor securely fixed?

Is drainage securely carried out?

Is earth line ( grounding ) securely connected? Is power supply voltage abided by the code? Is there any noise?

Is control display normal? Is cooling operation normal?

Is room temp. regulator normal?

27